{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2036-1XB40-0LA2","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2036-1XB40-0LA2","canonicalUrl":"https://aoctrl.com/siemens/3RT2036-1XB40-0LA2","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2036-1XB40-0LA2","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2036-1XB40-0LA2, size S2 power contactor, 24 V DC coil, screw terminals, 52 A rated at 480/600 V, DIN rail mount.","salesMarkdown":"## Siemens SIRIUS 3RT2036-1XB40-0LA2 — Size S2 Power Contactor, 24 V DC Coil It carries a 24 V DC coil with screw-type terminals, making it a direct-fit replacement or new-build component for 24 VDC control systems. The contactor is rated 52 A at both 480 V and 600 V, which means it handles full-load current for motors up to roughly 30 hp at 480 V — a common rating for medium-horsepower pumps, conveyors, and compressors in North American 480 V plants. The 52 A figure also covers resistive heating loads at those voltages. The S2 frame size is 114 mm high, 55 mm wide, and 130 mm deep. ## Ratings and Switching Performance The coil draws a 3 A inrush peak at 24 V DC. Closing time is 30 to 55 ms, arcing time 10 to 20 ms. The auxiliary switch is included. Switching frequency at AC-4 is rated at 250 operations per hour maximum.","metaTitle":"Siemens 3RT2036-1XB40-0LA2 SIRIUS Power Contactor, 24 V DC,","metaDescription":"Siemens SIRIUS 3RT2036-1XB40-0LA2 power contactor, size S2. 24 V DC coil, 52 A at 480/600 V. Screw terminals, DIN rail mount. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"130 mm","Width":"55 mm","at DC":"30 ... 55 ms","Height":"114 mm","Upwards":"10 mm","Forwards":"10 mm","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"6 mm","Rated Value":"24 V","Initial Value":"0.7","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Type Of Voltage":"DC","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-40 ... +70 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Full-Scale Value":"1.25","For Main Contacts":"18 ... 1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Inrush Current Peak":"3 A","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"52 A","at 500 V rated value":"2 A","at 600 V rated value":"52 A","at 690 V rated value":"1 A","Design Of The Product":"With extended operating range","Instantaneous Contact":"1","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"3 hp","at 200/208 V rated value":"15 hp","at 220/230 V rated value":"15 hp","at 460/480 V rated value":"40 hp","at 575/600 V rated value":"50 hp","at AC-2 at AC-3e maximum":"600 1/h","Locked-Rotor Current Peak":"2.6 A","Relative Humidity Minimum":"10 %","Holding Current Mean Value":"40 mA","at maximum Ith rated value":"25 mm²","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at maximum AC-1 rated value":"25 mm²","at AC in hot operating state":"12 W","at AC-2 at 400 V rated value":"22 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"41 A","Substance Prohibitance (Date)":"10/01/2014","Design Of The Surge Suppressor":"with varistor","Duration Of Inrush Current Peak":"50 µs","Locked-Rotor Current Mean Value":"1 A","Duration Of Locked-Rotor Current":"230 ms","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","Product Function Bus Communication":"No","With Type Of Assignment 2 Required":"gG: 80A (690V,100kA), aM: 50A (690V,100kA), BS88: 63A (415V,80kA)","Without Load Current Share Typical":"1 W","closing power of magnet coil at DC":"23 W","holding power of magnet coil at DC":"1 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 160 A (690 V, 100 kA), aM: 80 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"4 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","Type Of Voltage Of The Control Supply Voltage":"DC","up to 40 °C according to IEC 60077 rated value":"70 A","up to 70 °C according to IEC 60077 rated value":"55 A","Limited To 1 S Switching At Zero Current Maximum":"937 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"697 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"468 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"282 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"229 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/685bbf31a2fce449a832b99fae48eb36.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=458817&mlfb=3RT2036-1XB40-0LA2","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2036-1XB40-0LA2/alternatives.json"},"ai":{"faq":[{"question":"What is the coil voltage and type on this contactor?","answer":"It has a 24 V DC coil with screw-type terminals, drawing a 3 A inrush peak at pickup."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2036-1XB40-0LA2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2036-1XB40-0LA2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}