{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2036-3SF30","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2036-3SF30","canonicalUrl":"https://aoctrl.com/siemens/3RT2036-3SF30","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2036-3SF30","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S2, 3RT2036-3SF30, 83-150 V AC/DC coil, spring-type terminals, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"## Integrator's read on the 3RT2036-3SF30 MTBF sits at 52 a, which for a contactor in continuous duty is a solid reliability figure — not a consumable part you plan to swap on a PM schedule. That helps when the gland plate forces an odd orientation. Dimensions: 55 mm wide, 114 mm high, 130 mm deep. Clearances: 10 mm upward/downward/forward, 6 mm at the sides. The S2 frame is a standard footprint; it'll slot into a multi-contactor bank without surprises. ## Switching duty and coil draw Rated for AC-1 (resistive) at 1 000 ops/h, AC-3 (motor starting) at 800 ops/h, and AC-4 (plugging/inching) at 250 ops/h. Coil inrush peaks at 25 A, steady-state draw is 2 VA at 50 Hz or 60 Hz. Auxiliary switch is included — no add-on block needed for basic status feedback.","metaTitle":"Siemens 3RT2036-3SF30 SIRIUS Power Contactor, S2 Size, 83-15","metaDescription":"Siemens 3RT2036-3SF30 SIRIUS power contactor, size S2, 83-150 V AC/DC coil, spring-type terminals, MTBF 52 a. Current lifecycle stage. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"MTBF":"52 a","Depth":"130 mm","Width":"55 mm","at AC":"30 ... 55 ms","at DC":"30 ... 55 ms","Height":"114 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"2 VA","at 60 Hz":"2 VA","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"6 mm","Rated Value":"83 ... 150 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"600 1/h","at AC-3 maximum":"800 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Full-Scale Value":"1.1","at AC-3e maximum":"800 1/h","For Main Contacts":"18 ... 1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Inrush Current Peak":"25 A","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"5 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"52 A","at 50 Hz rated value":"83 ... 150 V","at 500 V rated value":"2 A","at 60 Hz rated value":"83 ... 150 V","at 600 V rated value":"52 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"3 hp","at 200/208 V rated value":"15 hp","at 220/230 V rated value":"15 hp","at 460/480 V rated value":"40 hp","at 575/600 V rated value":"50 hp","Locked-Rotor Current Peak":"0.8 A","Relative Humidity Minimum":"10 %","Holding Current Mean Value":"0.015 A","Of Main Circuit Rated Value":"6 kV","Safe failure fraction (SFF)":"96 %","Safety-Related Switching On":"No","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"12 W","at AC-2 at 400 V rated value":"22 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"41 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"01/29/2021","Design Of The Surge Suppressor":"with varistor","Duration Of Inrush Current Peak":"10 µs","Locked-Rotor Current Mean Value":"0.34 A","Duration Of Locked-Rotor Current":"230 ms","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"61.6 A","at AC-5b up to 400 V rated value":"41.5 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 80A (690V,100kA), aM: 50A (690V,100kA), BS88: 63A (415V,80kA)","Without Load Current Share Typical":"2 W","closing power of magnet coil at DC":"40 W","holding power of magnet coil at DC":"1.6 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 160 A (690 V, 100 kA), aM: 80 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)","category according to EN ISO 13849-1":"2","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"4 W","for AWG cables for auxiliary contacts":"2x (20 ... 14)","stop category according to EN 60204-1":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","voltage at PLC-control input rated value":"24 V","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Recovery Time After Power Failure Typical":"2.1 s","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","safety device type according to IEC 61508-2":"Type B","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC/DC","hardware fault tolerance according to IEC 61508":"0","Limited To 1 S Switching At Zero Current Maximum":"937 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"697 A; Use minimum cross-section acc. to AC-1 rated value","PFHD with high demand rate according to EN 62061":"7.7E-8 1/h","Limited To 10 S Switching At Zero Current Maximum":"468 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"282 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"229 A; Use minimum cross-section acc. to AC-1 rated value","SIL Claim Limit (subsystem) according to EN 62061":"2","PFDavg with low demand rate according to IEC 61508":"0.0067","performance level (PL) according to EN ISO 13849-1":"c","type of PLC-control input according to IEC 60947-1":"Type 1","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"5 000 000","operating range factor of the voltage at PLC-control input":"0.8 ... 1.1","Diagnostics Test Interval By Internal Test Function Maximum":"28 800 s","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"25 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/280821ca137c265b43bd770cdc870550.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1413424&mlfb=3RT2036-3SF30","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2036-3SF30/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT2036-3SF30 and get a price?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm number."},{"question":"What is the MTBF of the 3RT2036-3SF30?","answer":"The listed MTBF is 52 a. That's a reliability figure for continuous duty — not a part you'd schedule for routine replacement."},{"question":"Will 3RT2036-3SF30 drop into a panel specified around 3RT2015-1BW42?","answer":"Both are SIRIUS contactors, but the 3RT2036-3SF30 is an S2 frame while the 3RT2015-1BW42 is a smaller S0 frame. The S2 is wider (55 mm vs S0's typical 45 mm) and deeper. It won't drop into the same DIN footprint without panel rework — check the available rail space and enclosure depth before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2036-3SF30","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2036-3SF30 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}