{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2037-1KB40-1AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2037-1KB40-1AA0","canonicalUrl":"https://aoctrl.com/siemens/3RT2037-1KB40-1AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2037-1KB40-1AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2037-1KB40-1AA0 coupling contactor, size S2, 24 V DC coil, screw-type terminals, 3-pole main contacts, integrated auxiliary switch, 55 mm width, 130 mm depth, DIN rail mounting.","salesMarkdown":"The 3RT2037-1KB40-1AA0 is a SIRIUS coupling contactor in the size S2 frame, designed for switching loads where the coil circuit is electrically isolated from the main power circuit — common in safety interlocks, PLC-driven contactor banks, or any installation where the control voltage (here, 24 V DC) must not share a path with the load side. The coil draws a 2.6 A inrush peak and holds at 0.8 × the rated 24 V DC, so the PLC output or relay driving it must source that peak without voltage sag. ## Switching frequency and duty — where this contactor lives Maximum switching rates vary by load type: 800 operations/hour at AC-1 (resistive), 700 at AC-3 (squirrel-cage motors), 400 at AC-2 (slip-ring motors), and 200 at AC-4 (plugging/inching). The AC-3e rating also sits at 700 ops/hour. For a conveyor running at 30 starts per hour, this is plenty; for a high-cycle pick-and-place station, the AC-4 ceiling of 200 ops/hour is the hard limit. The main contact configuration is 3-pole (18…1), meaning three normally-open main contacts plus one normally-closed auxiliary contact built in. The auxiliary switch is included, so you don't need a separate side-mount block for basic feedback or status indication. Contact erosion depends on the switched current and duty class; at AC-3 rates, expect the electrical life to be shorter than the mechanical figure. ## Auxiliary contact breaking capacity — voltage matters If you're switching a 24 V DC PLC input, the 10 A rating is well above the typical 10-50 mA load, but at 220 V DC the contact is only good for 0.3 A — that's a hard limit for any DC-13 or resistive load at that voltage.","metaTitle":"Siemens 3RT2037-1KB40-1AA0 SIRIUS Contactor, S2, 24 V Coil","metaDescription":"Siemens 3RT2037-1KB40-1AA0 SIRIUS coupling contactor, size S2, 24 V DC coil, screw-type terminals. Active production, sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"130 mm","Width":"55 mm","Height":"114 mm","Arcing Time":"10 ... 20 ms","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/99b355274221736c27331269e064e2a7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=578162&mlfb=3RT2037-1KB40-1AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2037-1KB40-1AA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2037-1KB40-1AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2037-1KB40-1AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}