{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2037-1NP30","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2037-1NP30","canonicalUrl":"https://aoctrl.com/siemens/3RT2037-1NP30","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2037-1NP30","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, power contactor, 3RT2037-1NP30, S2 size, 175-280 VAC coil, screw-type terminals, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"The Siemens SIRIUS 3RT2037-1NP30 is a S2-size power contactor. The coil accepts 175...280 VAC. Rated for operating temperatures from -25 to +60 °C, it handles the heat inside a packed panel without derating. Storage range goes from -55 to +80 °C, meaning it survives a hot truck ride in summer or a cold warehouse in winter. The 3RT2037-1NP30 is rated for 800 switching cycles per hour at AC-1 (resistive loads) and 700 cycles per hour at AC-3 (standard motor starting). For heavy-duty jogging or plugging (AC-4 duty), it still manages 200 cycles per hour — enough for most reversing or inching applications on a conveyor or pump line. Coil inrush current peaks at 5 A, then settles to 2 VA at 50 or 60 Hz. That's a light load on a PLC output or control relay, so you don't need a dedicated interposing relay unless you're running a dozen of these off one transformer. Dimensions are 114 mm high, 55 mm wide, and 130 mm deep. The 55 mm width — three standard 18 mm module spaces — means it fits neatly on a DIN rail without crowding adjacent devices. Main contacts are rated for 18 A at the listed voltage range, with a 1.1 full-scale factor for short-duration overloads.","metaTitle":"Siemens SIRIUS 3RT2037-1NP30 Power Contactor, 175-280 VAC Co","metaDescription":"Siemens SIRIUS 3RT2037-1NP30 power contactor, S2 size, 175-280 VAC coil, screw terminals, DIN-rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"130 mm","Width":"55 mm","at AC":"30 ... 55 ms","at DC":"30 ... 55 ms","Height":"114 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"2 VA","at 60 Hz":"2 VA","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"6 mm","Rated Value":"175 ... 280 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"800 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"700 1/h","at AC-4 maximum":"200 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Full-Scale Value":"1.1","at AC-3e maximum":"700 1/h","For Main Contacts":"18 ... 1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Inrush Current Peak":"5 A","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"65 A","at 50 Hz rated value":"175 ... 280 V","at 500 V rated value":"2 A","at 60 Hz rated value":"175 ... 280 V","at 600 V rated value":"52 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"5 hp","at 200/208 V rated value":"20 hp","at 220/230 V rated value":"20 hp","at 460/480 V rated value":"50 hp","at 575/600 V rated value":"50 hp","Locked-Rotor Current Peak":"0.42 A","Relative Humidity Minimum":"10 %","Holding Current Mean Value":"6 mA","Of Main Circuit Rated Value":"6 kV","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"11.4 W","at AC-2 at 400 V rated value":"30 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"55 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2014","Design Of The Surge Suppressor":"with varistor","Duration Of Inrush Current Peak":"30 µs","Locked-Rotor Current Mean Value":"0.2 A","Duration Of Locked-Rotor Current":"230 ms","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"70.4 A","at AC-5b up to 400 V rated value":"53.9 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 125A (690V,100kA), aM: 63A (690V,100kA), BS88: 100A (415V,80kA)","Without Load Current Share Typical":"2 W","closing power of magnet coil at DC":"23 W","holding power of magnet coil at DC":"1 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"3.8 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"1 055 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"730 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"520 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"336 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"272 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"25 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d345ea1cad4a98edd6150eb9f39558da.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=62131&mlfb=3RT2037-1NP30","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2037-1NP30/alternatives.json"},"ai":{"faq":[{"question":"Will 3RT2037-1NP30 drop into a panel specified around 3RT2015-1BW42?","answer":"Both are SIRIUS S2-size contactors with the same DIN-rail mounting and similar terminal layout, so the 3RT2037-1NP30 will physically fit the same footprint and rail position. However, the coil voltage and current ratings differ — verify your control voltage (175-280 VAC for this unit) and load current before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2037-1NP30","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2037-1NP30 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}