{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2038-1AN60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2038-1AN60","canonicalUrl":"https://aoctrl.com/siemens/3RT2038-1AN60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2038-1AN60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S2, 3RT2038-1AN60, 65 A at 480 V AC-3, screw-type coil terminals, 200 V 50 Hz coil, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"## What fits in the panel ## What the 65 A rating means for motor loads The headline figure is 65 A at 480 V, but that is the AC-3 motor-switching rating — the one that governs real induction-motor duty on pumps, conveyors, and fans. At 480 V AC-3, this contactor handles 65 A of motor starting current, which corresponds roughly to a 50 hp motor at that voltage — enough for a medium compressor or a large conveyor drive. ## Coil voltage and control wiring The coil is wound for 200 V at 50 Hz, with a rated operating current of 0.36 A at 50 Hz and 0.39 A at 60 Hz — standard control transformer tap for European 400 V panels with a 200 V control bus. Coil terminals are screw-type, accepting 2x (0.5 to 1.5 mm²) solid or 2x (0.75 to 2.5 mm²) stranded — common sizes for control wiring in a panel. It carries an auxiliary switch (screw-terminal block), which means you can wire a feedback signal to the PLC without adding a separate auxiliary contact block for basic status monitoring.","metaTitle":"Siemens 3RT2038-1AN60 SIRIUS Power Contactor, 65 A at 480 V","metaDescription":"Siemens 3RT2038-1AN60 SIRIUS power contactor, 65 A AC-3 at 480 V, Size S2, screw terminals, 200 V 50 Hz coil. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"130 mm","Width":"55 mm","at AC":"10 ... 18 ms","title":"3RT2038-1AN60","Height":"114 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.36","at 60 Hz":"0.39","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"6 mm","description":"power contactor, AC-3e/AC-3, 80 A, 37 kW / 400 V, 3-pole, 200 V AC, 50 Hz / 200-220 V, 60 Hz, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S2","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"700 1/h","at AC-2 maximum":"350 1/h","at AC-3 maximum":"500 1/h","at AC-4 maximum":"150 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"500 1/h","For Main Contacts":"18 ... 1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"15 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.6 A","at 480 V rated value":"65 A","at 50 Hz rated value":"200 V","at 500 V rated value":"2 A","at 60 Hz rated value":"200 ... 220 V","at 600 V rated value":"62 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"5 hp","at 200/208 V rated value":"20 hp","at 220/230 V rated value":"25 hp","at 460/480 V rated value":"50 hp","at 575/600 V rated value":"60 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","Safety-Related Switching On":"Yes","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"17.1 W","at AC-2 at 400 V rated value":"37 kW","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"55 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"10/01/2014","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"79.2 A","at AC-5b up to 400 V rated value":"66.4 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 160A (690V,100kA), aM: 80A (690V,100kA), BS88: 125A (415V,80kA)","Without Load Current Share Typical":"17.2 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"5.7 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"1 298 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"898 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"640 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"414 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"333 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"35 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5c37aae7c47c56a93b1e36ceeb11e942.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1382437&mlfb=3RT2038-1AN60"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2038-1AN60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2038-1AN60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}