{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2045-1AP00-1AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2045-1AP00-1AA0","canonicalUrl":"https://aoctrl.com/siemens/3RT2045-1AP00-1AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2045-1AP00-1AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2045-1AP00-1AA0 power contactor, Size S3, 77 A at 480 V, 15 hp at 230 V, 3-pole, screw-type coil terminals, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"## Panel Fit and Mounting The 3RT2045-1AP00-1AA0 is a Size S3 power contactor from the SIRIUS family, designed for screw and snap-on mounting onto a 35 mm standard mounting rail per DIN EN 60715. Its dimensions — 70 mm width, 140 mm height, 152 mm depth — define the enclosure cutout and the spacing to adjacent components. Minimum clearance requirements: 10 mm upwards, 20 mm forwards, 10 mm downwards, and 10 mm at the side. These clearances handle arc venting and cooling airflow; crowding them derates the switching capacity. Mounting position is standing on a horizontal surface — the contactor is not rated for vertical or inverted orientation without derating the thermal budget. ## Wire Termination and Auxiliary Contacts Main power terminals accept solid wire from 2.5 mm² up to 16 mm², and stranded wire from 6 mm² up to 70 mm². The magnet coil uses screw-type terminals — no spring-cage option on this variant. A built-in auxiliary switch is included (10... 2 configuration for main contacts). Auxiliary contact wiring accepts 2x (0.5... 1.5 mm²) or 2x (0.75... 2.5 mm²) solid or stranded wire. The auxiliary contacts are rated for 10 A at 24 V, 2 A at 48 V, 2 A at 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 0.8 A at 440 V — covering PLC-level feedback and interposing relay loads. ## Duty Ratings and Switching Rates Rated 77 A at 480 V and 15 hp at 230 V — this is the AC-3 motor switching rating. The contactor handles resistive loads (AC-1) at up to 900 switching operations per hour, squirrel-cage motors (AC-3) at 1,000 ops/h, slip-ring motors (AC-2) at 400 ops/h, and plugging/inching duty (AC-4) at 300 ops/h. The AC-3e rating for energy-efficient motors is also 1,000 ops/h maximum. Operating time on AC is 10... 21 ms, with an arcing time of 10... 20 ms. The power factor at 50 Hz is 0.38 — this affects the contact erosion rate in inductive loads. Mechanical life is 10,000,000 operations typical. Operating temperature range is -25 to +60 °C; storage range is -55 to +80 °C. The 60 °C ceiling means the contactor can sit in a non-air-conditioned panel in a factory hall, but the switching rate must be derated above 40 °C per the Siemens application manual.","metaTitle":"Siemens 3RT2045-1AP00-1AA0 SIRIUS Power Contactor","metaDescription":"Siemens 3RT2045-1AP00-1AA0 SIRIUS power contactor, Size S3, 77 A at 480 V, screw-type terminals, 35 mm DIN rail mount, current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"152 mm","Solid":"2.5 ... 16 mm²","Width":"70 mm","at AC":"10 ... 21 ms","title":"3RT2045-1AP00-1AA0","Height":"140 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"6 ... 70 mm²","at 50 Hz":"0.38","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"10 mm","description":"power contactor, AC-3e/AC-3, 80 A, 37 kW / 400 V, 3-pole, 230 V AC, 50 Hz, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S3, upright mounting position","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"900 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","at AC-3e maximum":"1 000 1/h","For Main Contacts":"10 ... 2","Mounting Position":"standing, on horizontal mounting surface","Size Of Contactor":"S3","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"15 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.8 A","at 480 V rated value":"77 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 600 V rated value":"62 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"37 kW","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"7.5 hp","at 200/208 V rated value":"25 hp","at 220/230 V rated value":"30 hp","at 460/480 V rated value":"60 hp","at 575/600 V rated value":"60 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Safety-Related Switching On":"Yes","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"15.9 W","at AC-2 at 400 V rated value":"37 kW","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"66 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"03/01/2017","at AWG cables for main contacts":"2x (10 ... 1/0), 1x (10 ... 2)","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"110 A","at AC-5b up to 400 V rated value":"80 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 160A (690V,100kA), aM: 80A (690V,100kA), BS88: 125A (415V,80kA)","Without Load Current Share Typical":"19 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"5.3 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"1 500 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"1 186 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"851 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"538 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"423 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"50 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7d28fa7380658c541019ac8751bc4da6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629783&mlfb=3RT2045-1AP00-1AA0"},"ai":{"faq":[{"question":"What compliance documentation does Siemens provide for 3RT2045-1AP00-1AA0?","answer":"The part carries the SIRIUS brand designation and is manufactured to IEC/EN 60947-4-1 standards for contactors. RoHS and REACH compliance documentation is available from Siemens upon request; UL and CSA approvals are standard for the SIRIUS contactor family, though specific file numbers are not listed in this spec record."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2045-1AP00-1AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2045-1AP00-1AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}