{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2045-3AM20","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2045-3AM20","canonicalUrl":"https://aoctrl.com/siemens/3RT2045-3AM20","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2045-3AM20","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S3 power contactor, 3RT2045-3AM20, screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715, spring-type coil terminals, 140 x 70 x 152 mm (H x W x D).","salesMarkdown":"## SIRIUS S3 Power Contactor – Panel Fit and Lifecycle Read Clearance distances are 10 mm upwards, downwards, and to the side, and 20 mm forwards — plan your gland plate and busbar layout accordingly. ## Duty Ratings and Switching Frequency This contactor is rated for different switching frequencies depending on the duty class: 900 operations per hour at AC-1 (resistive), 400 at AC-2 (slip-ring motors), 1,000 at AC-3 (squirrel-cage motors), and 300 at AC-4 (plugging/inching). The AC-3e maximum is also 1,000 ops/h. For a typical conveyor or pump motor on AC-3 duty, that means you can cycle it every 3.6 seconds continuously — well within the demands of most automated lines. Auxiliary contacts are present and carry rated currents from 10 A at 24 V down to 0.3 A at 220 V, with a 15 hp rating at 230 V. Operating time at AC is 10 to 21 ms, arcing time 10 to 20 ms — fast enough for most control schemes but verify coordination with your PLC scan cycle if you're using the auxiliary for feedback. Compliance documentation typically includes RoHS, REACH, and IEC/EN 60947-4-1 declarations from Siemens. The DIN rail mounting standard (DIN EN 60715) is cited, and the spring-type coil terminals eliminate the need for screw tightening on the control circuit — a time-saver during panel build.","metaTitle":"Siemens 3RT2045-3AM20 SIRIUS S3 Power Contactor, Spring-Term","metaDescription":"Siemens SIRIUS S3 power contactor 3RT2045-3AM20. Screw and snap-on 35 mm DIN rail. Spring-type coil terminals. Operating temp -25 to +60 °C. Current lifecycle stage. Available to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"152 mm","Solid":"2.5 ... 16 mm²","Width":"70 mm","at AC":"10 ... 21 ms","Height":"140 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"6 ... 70 mm²","at 50 Hz":"0.35","at 60 Hz":"0.41","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"10 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"900 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"1 000 1/h","For Main Contacts":"10 ... 2","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S3","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"15 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.8 A","at 480 V rated value":"77 A","at 50 Hz rated value":"208 V","at 500 V rated value":"2 A","at 60 Hz rated value":"208 V","at 600 V rated value":"62 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"37 kW","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"7.5 hp","at 200/208 V rated value":"25 hp","at 220/230 V rated value":"30 hp","at 460/480 V rated value":"60 hp","at 575/600 V rated value":"60 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Safety-Related Switching On":"Yes","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"15.9 W","at AC-2 at 400 V rated value":"37 kW","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"66 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"03/01/2017","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"110 A","at AC-5b up to 400 V rated value":"80 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 160A (690V,100kA), aM: 80A (690V,100kA), BS88: 125A (415V,80kA)","Without Load Current Share Typical":"25 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"5.3 W","for AWG cables for auxiliary contacts":"2x (20 ... 16)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"1 500 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"1 186 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"851 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"538 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"423 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"50 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7d28fa7380658c541019ac8751bc4da6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629824&mlfb=3RT2045-3AM20","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2045-3AM20/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT2045-3AM20 and how do I get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ to get a firm price and lead time."},{"question":"What are the key dimensions for panel layout?","answer":"Height 140 mm, width 70 mm, depth 152 mm. Clearances: 10 mm upwards, downwards, and to the side; 20 mm forwards. Mounts on 35 mm DIN rail per DIN EN 60715."},{"question":"What conductor sizes does 3RT2045-3AM20 accept?","answer":"Solid conductors 2.5 to 16 mm², stranded 6 to 70 mm². The coil terminals are spring-type, accepting 2x (0.5 to 2.5 mm²) solid or stranded."},{"question":"Will 3RT2045-3AM20 drop into a panel specified around 3RT1054-2AP36?","answer":"Both are SIRIUS S3 frame contactors with the same 35 mm DIN rail footprint, so the mechanical fit is identical. The 3RT2045-3AM20 uses spring-type coil terminals versus the screw-type on the 3RT1054-2AP36, so verify your control wiring terminations — no rewiring of the main power connections is needed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2045-3AM20","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2045-3AM20 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}