{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2046-1AN24","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2046-1AN24","canonicalUrl":"https://aoctrl.com/siemens/3RT2046-1AN24","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2046-1AN24","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT2046-1AN24, size S3, screw-type terminals, auxiliary switch, screw and snap-on mounting on 35 mm DIN rail (DIN EN 60715).","salesMarkdown":"Storage range extends to -55 °C to +80 °C, which governs handling and warehousing, not running. For AC-3 motor switching (the standard squirrel-cage duty), it's rated at 850 operations per hour maximum; AC-4 (plugging/reversing) drops to 250 ops/h. The AC-1 resistive load rating allows 900 ops/h. These numbers set the thermal cycling limit for the coil and arc chamber, not the mechanical armature. Auxiliary contact ratings: 6 A at 24 V, 2 A at 48/60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, 0.8 A at 440 V. These are the make/break limits for the control circuit — useful for interlocking or PLC input circuits. The 230 V rating is given as 20 hp, which aligns with a typical motor load for this contactor size. ## Wiring and panel integration Solid wire accepted: 2.5 to 16 mm²; stranded: 6 to 70 mm². The screw terminals accept two conductors per clamp for daisy-chaining: 2x (0.5 to 1.5 mm²) solid or stranded, or 2x (0.75 to 2.5 mm²). Dimensions: 70 mm wide, 140 mm high, 195 mm deep. The depth is the critical clearance dimension for enclosure depth.","metaTitle":"Siemens 3RT2046-1AN24 SIRIUS Power Contactor, S3, 70 mm","metaDescription":"Siemens 3RT2046-1AN24 SIRIUS power contactor, size S3, screw terminals, auxiliary switch, 70 mm width, 195 mm depth. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"195 mm","Solid":"2.5 ... 16 mm²","Width":"70 mm","at AC":"10 ... 21 ms","Height":"140 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"6 ... 70 mm²","at 50 Hz":"0.35","at 60 Hz":"0.41","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"10 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"900 1/h","at AC-2 maximum":"350 1/h","at AC-3 maximum":"850 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","at AC-3e maximum":"850 1/h","For Main Contacts":"10 ... 2","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S3","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"6 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"20 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.8 A","at 480 V rated value":"96 A","at 50 Hz rated value":"220 V","at 500 V rated value":"2 A","at 60 Hz rated value":"220 V","at 600 V rated value":"77 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"37 kW","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"10 hp","at 200/208 V rated value":"30 hp","at 220/230 V rated value":"30 hp","at 460/480 V rated value":"75 hp","at 575/600 V rated value":"75 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Safety-Related Switching On":"Yes","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"19.8 W","at AC-2 at 400 V rated value":"45 kW","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"80 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"03/01/2017","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"114 A","at AC-5b up to 400 V rated value":"95 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 160 A (690 V, 100 kA), aM: 100 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)","Without Load Current Share Typical":"25 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"6.6 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"1 725 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"1 297 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"946 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"610 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"486 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"50 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7d28fa7380658c541019ac8751bc4da6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629866&mlfb=3RT2046-1AN24","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2046-1AN24/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RT2046-1AN24?","answer":"195 mm. That is the dimension from the mounting surface to the furthest projection — critical for enclosure depth planning."},{"question":"What solid wire range does 3RT2046-1AN24 accept?","answer":"Solid wire: 2.5 to 16 mm² per clamp. Stranded: 6 to 70 mm². Also accepts two conductors per clamp: 2x (0.5 to 1.5 mm²) solid or stranded, or 2x (0.75 to 2.5 mm²)."},{"question":"Will 3RT2046-1AN24 drop into a panel specified for 3RT1264-6AP36-0KA1?","answer":"Both are SIRIUS size S3 contactors with the same DIN-rail footprint, so the mechanical fit is identical. The difference is in the coil voltage and auxiliary contact configuration — check the coil rating on the nameplate before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2046-1AN24","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2046-1AN24 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}