{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2046-1NF34","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2046-1NF34","canonicalUrl":"https://aoctrl.com/siemens/3RT2046-1NF34","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2046-1NF34","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, S3 frame, screw-type coil terminals, 83-155 V AC/DC coil, 195 mm depth, 70 mm width, 140 mm height.","salesMarkdown":"## Siemens 3RT2046-1NF34 — SIRIUS S3 Power Contactor It carries a coil rated at 83-155 V, drawing 3.5 VA at both 50 Hz and 60 Hz, with an inrush current peak of 1.5 A. The main contacts are screw-type terminals accepting solid conductors from 2.5 to 16 mm² and stranded from 6 to 70 mm². ## Duty Ratings and Switching Frequency Switching frequency varies by duty class: 900 operations per hour at AC-1 (resistive), 850 at AC-3 and AC-3e (squirrel-cage motor starting), 350 at AC-2 (slip-ring motor), and 250 at AC-4 (plugging/inching). The arcing time is 10-20 ms, and the operating time (both AC and DC) is 38-57 ms. These ratings define the thermal cycling limits for the contactor in a given application — AC-3 is the typical motor-switching duty, and the 850 ops/h ceiling means it handles moderate cycling on a conveyor or pump without exceeding thermal rise limits. ## Auxiliary Contacts and Environmental Range An auxiliary switch is included. Its rated values at different voltages: 6 A at 24 V, 2 A at 48 V, 2 A at 60 V, 1 A at 110 V. The contactor is rated for a full-scale value of 1.1 (likely the rated operational current multiplier for overload conditions) and an initial value of 0.8 (possibly the pick-up voltage threshold relative to rated).","metaTitle":"Siemens 3RT2046-1NF34 SIRIUS Power Contactor, S3, 83-155 V C","metaDescription":"Siemens SIRIUS 3RT2046-1NF34 power contactor, S3 size, screw terminals, 83-155 V AC/DC coil. Current lifecycle stage. Available to order. Depth 195 mm, width 70 mm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"195 mm","Solid":"2.5 ... 16 mm²","Width":"70 mm","at AC":"38 ... 57 ms","at DC":"38 ... 57 ms","Height":"140 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"6 ... 70 mm²","at 50 Hz":"3.5 VA","at 60 Hz":"3.5 VA","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"10 mm","Rated Value":"83 ... 155 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"900 1/h","at AC-2 maximum":"350 1/h","at AC-3 maximum":"850 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","Full-Scale Value":"1.1","at AC-3e maximum":"850 1/h","For Main Contacts":"10 ... 2","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S3","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Inrush Current Peak":"1.5 A","Product Designation":"Power contactor","at 24 V rated value":"6 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"20 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.8 A","at 480 V rated value":"96 A","at 50 Hz rated value":"83 ... 155 V","at 500 V rated value":"2 A","at 60 Hz rated value":"83 ... 155 V","at 600 V rated value":"77 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"37 kW","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"10 hp","at 200/208 V rated value":"30 hp","at 220/230 V rated value":"30 hp","at 460/480 V rated value":"75 hp","at 575/600 V rated value":"75 hp","Locked-Rotor Current Peak":"2.7 A","Relative Humidity Minimum":"10 %","Holding Current Mean Value":"15 mA","Of Main Circuit Rated Value":"8 kV","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"19.8 W","at AC-2 at 400 V rated value":"45 kW","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"80 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"03/01/2017","Design Of The Surge Suppressor":"with varistor","Duration Of Inrush Current Peak":"50 µs","Locked-Rotor Current Mean Value":"1.1 A","at AWG cables for main contacts":"2x (10 ... 1/0), 1x (10 ... 2)","Duration Of Locked-Rotor Current":"150 ms","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"114 A","at AC-5b up to 400 V rated value":"95 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 160 A (690 V, 100 kA), aM: 100 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)","Without Load Current Share Typical":"3.5 W","closing power of magnet coil at DC":"76 W","holding power of magnet coil at DC":"2.7 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"6.6 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"1 725 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"1 297 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"946 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"610 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"486 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"50 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7d28fa7380658c541019ac8751bc4da6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629893&mlfb=3RT2046-1NF34","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2046-1NF34/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source for 3RT2046-1NF34?","answer":"The 3RT1054-1AB36 is a peer in the same SIRIUS contactor family but in a different frame size (S2 vs S3). The 3RT2046-1NF34 is an S3 frame; the 3RT1054-1AB36 is an S2. Panel fit and terminal spacing differ — verify mechanical dimensions before substituting."},{"question":"What wire sizes does the 3RT2046-1NF34 accept?","answer":"Solid conductors: 2.5 to 16 mm². Stranded conductors: 6 to 70 mm². Auxiliary terminals accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²)."},{"question":"Will 3RT2046-1NF34 drop into a panel specified for 3RT1054-1AB36?","answer":"Not without checking mechanical fit — the 3RT2046-1NF34 is an S3 frame, while the 3RT1054-1AB36 is an S2 frame. Dimensions and DIN rail footprint differ. Verify panel cutout and terminal alignment before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2046-1NF34","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2046-1NF34 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}