{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2046-3AF04","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2046-3AF04","canonicalUrl":"https://aoctrl.com/siemens/3RT2046-3AF04","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2046-3AF04","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, power contactor, size S3, order code 3RT2046-3AF04, 96 A at 480 V, spring-type coil terminals, screw and snap-on mounting.","salesMarkdown":"## SIRIUS S3 power contactor — 96 A at 480 V, spring-coil terminals, DIN-rail ready It mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715, with a 70 x 140 x 198 mm footprint that fits standard enclosure backplates. The coil connection uses spring-type terminals — no screw torque check needed on the coil side, which saves a step during panel build. ## Wire range and auxiliary contact Main power terminals accept solid conductors from 2.5 to 16 mm² and stranded conductors from 6 to 70 mm², covering the range from control-circuit tap-offs to motor feeders. ## Switching frequency by duty class Maximum switching rates are specified per duty: 900 cycles/hour at AC-1 (resistive), 850 at AC-3 and AC-3e (standard motor starting), 350 at AC-2 (slip-ring motor), and 250 at AC-4 (plugging/inching). For a conveyor line running AC-3 duty at 850 ops/hour, that's roughly one start every 4.2 seconds continuous — enough for high-speed pick-and-place but not for a stamping press running full AC-4 reversals.","metaTitle":"Siemens 3RT2046-3AF04 SIRIUS Power Contactor, 96 A at 480 V,","metaDescription":"Siemens SIRIUS 3RT2046-3AF04 power contactor, size S3, rated 96 A at 480 V AC-3. Spring-type coil terminals, screw and snap-on DIN rail mount. Current lifecycle. Available to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"198 mm","Solid":"2.5 ... 16 mm²","Width":"70 mm","at AC":"10 ... 21 ms","title":"3RT2046-3AF04","Height":"140 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"6 ... 70 mm²","at 50 Hz":"0.38","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"10 mm","description":"power contactor, AC-3e/AC-3, 95 A, 45 kW / 400 V, 3-pole, 110 V AC, 50 Hz, auxiliary contacts: 2 NO + 2 NC, main circuit: screw terminal, control and auxiliary circuit: spring-loaded terminal, size: S3, removable auxiliary switch","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","at AC-1 maximum":"900 1/h","at AC-2 maximum":"350 1/h","at AC-3 maximum":"850 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","at AC-3e maximum":"850 1/h","For Main Contacts":"10 ... 2","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S3","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"6 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"20 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.8 A","at 480 V rated value":"96 A","at 50 Hz rated value":"110 V","at 500 V rated value":"2 A","at 600 V rated value":"77 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"37 kW","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"10 hp","at 200/208 V rated value":"30 hp","at 220/230 V rated value":"30 hp","at 460/480 V rated value":"75 hp","at 575/600 V rated value":"75 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"19.8 W","at AC-2 at 400 V rated value":"45 kW","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"80 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"03/01/2017","at AWG cables for main contacts":"2x (10 ... 1/0), 1x (10 ... 2)","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"114 A","at AC-5b up to 400 V rated value":"95 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 160 A (690 V, 100 kA), aM: 100 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)","Without Load Current Share Typical":"19 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"6.6 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"1 725 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"1 297 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"946 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"610 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"486 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"50 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7d28fa7380658c541019ac8751bc4da6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629902&mlfb=3RT2046-3AF04"},"ai":{"faq":[{"question":"Where can I buy 3RT2046-3AF04 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time."},{"question":"What is 3RT2046-3AF04's listed depth?","answer":"The depth is 198 mm, with a width of 70 mm and height of 140 mm."},{"question":"What wire sizes does 3RT2046-3AF04 accept?","answer":"Solid conductors from 2.5 to 16 mm² and stranded conductors from 6 to 70 mm²."},{"question":"Will 3RT2046-3AF04 drop into a panel specified around 3RT1264-6AP36-0KA1 without rewiring?","answer":"Both are SIRIUS S3-size contactors with the same 70 x 140 x 198 mm footprint and DIN-rail mounting, so mechanical fit is identical. The 3RT2046-3AF04 uses spring-type coil terminals versus the screw-type on some SIRIUS variants — verify coil wiring termination style before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2046-3AF04","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2046-3AF04 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}