{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2046-3XJ40-0LA2","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2046-3XJ40-0LA2","canonicalUrl":"https://aoctrl.com/siemens/3RT2046-3XJ40-0LA2","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2046-3XJ40-0LA2","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2046-3XJ40-0LA2 power contactor, S3 frame, 96 A at 480 V AC-3, 72 V DC coil, spring-type terminals, screw and snap-on DIN rail mounting.","salesMarkdown":"## 96 A at 480 V — the motor-switching ceiling The 3RT2046-3XJ40-0LA2: The 96 A rating at 480 V sets the AC-3 motor-switching ceiling for this SIRIUS S3-frame contactor. That is the number that decides whether it handles the load on your pump, conveyor, or compressor without welding the main contacts on break. The 72 V DC coil with a 38 to 57 ms operating range means the PLC output stage must deliver that DC bus voltage and hold it long enough for the magnet to pull in — a 24 V DC pilot relay won't cut it. ## Panel fit and mounting flexibility The screw and snap-on fastening lets you pre-mount the contactor on a rail segment and slide it into the enclosure, saving time on a multi-contactor panel. That gives layout flexibility in tight cabinets — the contactor can sit sideways or angled as long as the arc space is respected. The 20 mm forward gap is the one that catches people — arc gases need that space to vent without tracking to adjacent metal. ## Wiring and environmental limits Spring-type terminals on the coil — no screw tightening, no vibration loosening. Operating temperature -40 to +70 °C with storage down to -55 °C. That -40 °C low end matters for cold-environment installations like refrigerated warehouses or outdoor enclosures in northern climates — the coil magnetisation holds at that temperature. Mechanical life 10 million operations typical, with AC-4 switching limited to 250 operations per hour. The AC-4 ceiling governs plugging and inching duty — if your application reverses the motor under load, stay under 250 cycles/hour or the arc erosion accelerates.","metaTitle":"Siemens 3RT2046-3XJ40-0LA2 SIRIUS Power Contactor","metaDescription":"Siemens 3RT2046-3XJ40-0LA2 SIRIUS power contactor, S3 frame, 96 A at 480 V AC-3. DC coil 72 V, spring terminals, DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"152 mm","Width":"70 mm","at DC":"38 ... 57 ms","title":"3RT2046-3XJ40-0LA2","Height":"140 mm","Upwards":"10 mm","Forwards":"20 mm","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"10 mm","Rated Value":"72 V","description":"traction contactor, AC-3e/AC-3, 95 A, 45 kW / 400 V, 3-pole, 72 V DC, 0.7-1.25* Us, electronic drive, with integrated varistor, auxiliary contacts: 1 NO + 1 NC, main circuit: screw terminal, control and auxiliary circuit: spring-loaded terminal, size: S3","Initial Value":"0.7","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","Type Of Voltage":"DC","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-40 ... +70 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Full-Scale Value":"1.25","For Main Contacts":"10 ... 2","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S3","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"20 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.8 A","at 480 V rated value":"96 A","at 500 V rated value":"2 A","at 600 V rated value":"77 A","at 690 V rated value":"1 A","Design Of The Product":"With extended operating range","Instantaneous Contact":"1","Side-By-Side Mounting":"Yes","at 1000 V rated value":"37 kW","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"10 hp","at 200/208 V rated value":"30 hp","at 220/230 V rated value":"30 hp","at 460/480 V rated value":"75 hp","at 575/600 V rated value":"75 hp","at AC-2 at AC-3e maximum":"350 1/h","Relative Humidity Minimum":"10 %","at maximum Ith rated value":"50 mm²","Of Main Circuit Rated Value":"8 kV","at AC-3 rated value maximum":"1 000 V","at maximum AC-1 rated value":"50 mm²","at AC in hot operating state":"19.8 W","at AC-2 at 400 V rated value":"45 kW","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"80 A","Substance Prohibitance (Date)":"03/01/2017","Design Of The Surge Suppressor":"with varistor","Duration Of Locked-Rotor Current":"150 ms","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","Product Function Bus Communication":"No","With Type Of Assignment 2 Required":"gG: 160 A (690 V, 100 kA), aM: 100 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)","Without Load Current Share Typical":"1 W","closing power of magnet coil at DC":"64 W","holding power of magnet coil at DC":"1 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"6.6 W","for AWG cables for auxiliary contacts":"2x (20 ... 16)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","Type Of Voltage Of The Control Supply Voltage":"DC","up to 40 °C according to IEC 60077 rated value":"130 A","up to 70 °C according to IEC 60077 rated value":"95 A","Limited To 1 S Switching At Zero Current Maximum":"1 725 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"1 297 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"946 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"610 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"486 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7d28fa7380658c541019ac8751bc4da6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629922&mlfb=3RT2046-3XJ40-0LA2"},"ai":{"faq":[{"question":"What is the 3RT2046-3XJ40-0LA2 rated for at 480 V?","answer":"96 A at 480 V in AC-3 duty — that is the motor-switching current for standard squirrel-cage motors."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2046-3XJ40-0LA2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2046-3XJ40-0LA2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}