{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2047-1AK64-3MA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2047-1AK64-3MA0","canonicalUrl":"https://aoctrl.com/siemens/3RT2047-1AK64-3MA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2047-1AK64-3MA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S3, screw and snap-on DIN rail mount, 70 mm width, 195 mm depth, 140 mm height, auxiliary switch included.","salesMarkdown":"It includes an integrated auxiliary switch, and its 70 mm width, 195 mm depth, and 140 mm height define the panel footprint for this size class. ## Duty-cycle and switching frequency Switching frequency depends on the duty category: AC-1 (resistive) allows up to 900 operations per hour, AC-3 (squirrel-cage motor start/run) allows 850 1/h, while AC-4 (plugging/inching) is limited to 200 1/h. The AC-3e maximum matches the AC-3 figure at 850 1/h. Main contact terminals accept solid conductors from 2.5 to 16 mm² and stranded conductors from 6 to 70 mm². The magnet coil uses screw-type terminals. Auxiliary contact wiring accepts two conductors per terminal: 2x (0.5 to 1.5 mm²) solid or stranded, or 2x (0.75 to 2.5 mm²). The contactor is rated for 10 million typical mechanical operations. The integrated auxiliary switch is rated at 6 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, and 3 A at 400 V. At 230 V the rating is 20 hp.","metaTitle":"Siemens 3RT2047-1AK64-3MA0 SIRIUS Power Contactor, S3, 70 mm","metaDescription":"Siemens SIRIUS 3RT2047-1AK64-3MA0 power contactor, Size S3, 70 mm width, screw and snap-on DIN rail mount. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"195 mm","Solid":"2.5 ... 16 mm²","Width":"70 mm","at AC":"10 ... 21 ms","title":"3RT2047-1AK64-3MA0","Height":"140 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"6 ... 70 mm²","at 50 Hz":"0.36","at 60 Hz":"0.4","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"10 mm","description":"power contactor, AC-3e/AC-3, 110 A, 55 kW / 400 V, 3-pole, 110 V AC, 50 Hz / 120 V, 60 Hz, auxiliary contacts: 2 NO + 2 NC, screw terminal, size: S3, captive auxiliary switch","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"900 1/h","at AC-2 maximum":"350 1/h","at AC-3 maximum":"850 1/h","at AC-4 maximum":"200 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","at AC-3e maximum":"850 1/h","For Main Contacts":"10 ... 2","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S3","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"6 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"20 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.8 A","at 480 V rated value":"96 A","at 50 Hz rated value":"110 V","at 500 V rated value":"2 A","at 60 Hz rated value":"120 V","at 600 V rated value":"99 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"37 kW","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"10 hp","at 200/208 V rated value":"30 hp","at 220/230 V rated value":"40 hp","at 460/480 V rated value":"75 hp","at 575/600 V rated value":"100 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Safety-Related Switching On":"Yes","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"23.7 W","at AC-2 at 400 V rated value":"55 kW","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"97 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"03/01/2017","at AWG cables for main contacts":"2x (10 ... 1/0), 1x (10 ... 2)","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"120 A","at AC-5b up to 400 V rated value":"110 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 200A (690V,100kA), aM: 100A (690V,100kA), BS88: 160A (415V,80kA)","Without Load Current Share Typical":"22 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"7.9 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"1 960 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"1 502 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"1 095 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"707 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"562 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"50 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7d28fa7380658c541019ac8751bc4da6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629931&mlfb=3RT2047-1AK64-3MA0"},"ai":{"faq":[{"question":"Where can I buy 3RT2047-1AK64-3MA0 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the depth of 3RT2047-1AK64-3MA0?","answer":"The depth is 195 mm."},{"question":"What wire sizes does the main contact accept?","answer":"Solid conductors from 2.5 to 16 mm² and stranded conductors from 6 to 70 mm²."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2047-1AK64-3MA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2047-1AK64-3MA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}