{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2047-1NB30-1AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2047-1NB30-1AA0","canonicalUrl":"https://aoctrl.com/siemens/3RT2047-1NB30-1AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2047-1NB30-1AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2047-1NB30-1AA0, Size S3 power contactor, 20-33 V coil, screw terminals, auxiliary switch, 70 x 140 x 152 mm.","salesMarkdown":"The Siemens 3RT2047-1NB30-1AA0 is a SIRIUS-brand power contactor, Size S3. Coil voltage range is 20-33 V. AC-4 (plugging/reversing) drops to 200 cycles per hour — that's the thermal limit of the arc chamber during frequent inrush. Arcing time is 10-20 ms, and the make/break times at both AC and DC are 38-57 ms, which is typical for a contactor of this frame size and gives the PLC enough time to confirm state before the next command. Rated switching capacity at 24 V is 10 A, dropping to 2 A at 48 V and 60 V, and 1 A at 110 V. That covers most PLC input card and indicator lamp loads without a relay interposer. The inrush current peak is 6.5 A. For BOM freeze or second-source planning, the closest functional peer within the SIRIUS family is the 3RT2036-1AC20-ZX95, which shares the same Size S3 frame and screw-terminal design. The deciding difference is coil voltage — the 3RT2036-1AC20-ZX95 uses a 24 V AC/DC coil, while this unit runs on 20-33 V DC. Verify your control voltage before substituting. Stranded conductor range up to 70 mm² means a single contactor can terminate a 35 mm² motor feed directly, no terminal block needed for the power circuit. At AC-3 duty of 850 cycles/hour.","metaTitle":"Siemens 3RT2047-1NB30-1AA0 SIRIUS Power Contactor","metaDescription":"Siemens 3RT2047-1NB30-1AA0 SIRIUS power contactor, Size S3, 20-33 V coil voltage, screw terminals, auxiliary switch. Current lifecycle stage, available to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"152 mm","Solid":"2.5 ... 16 mm²","Width":"70 mm","at AC":"38 ... 57 ms","at DC":"38 ... 57 ms","title":"3RT2047-1NB30-1AA0","Height":"140 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"6 ... 70 mm²","at 50 Hz":"3.5 VA","at 60 Hz":"3.5 VA","Downwards":"10 mm","Arcing Time":"10 ... 20 ms","At The Side":"10 mm","Rated Value":"20 ... 33 V","description":"power contactor, AC-3e/AC-3, 110 A, 55 kW / 400 V, 3-pole, 20-33 V AC/DC, 50/60 Hz, with integrated varistor, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S3, upright mounting position","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"900 1/h","at AC-2 maximum":"350 1/h","at AC-3 maximum":"850 1/h","at AC-4 maximum":"200 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","Full-Scale Value":"1.1","at AC-3e maximum":"850 1/h","For Main Contacts":"10 ... 2","Mounting Position":"standing, on horizontal mounting surface","Size Of Contactor":"S3","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Inrush Current Peak":"6.5 A","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"20 hp","at 400 V rated value":"3 A","at 440 V rated value":"0.8 A","at 480 V rated value":"96 A","at 50 Hz rated value":"20 ... 33 V","at 500 V rated value":"2 A","at 60 Hz rated value":"20 ... 33 V","at 600 V rated value":"99 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"37 kW","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","at 110/120 V rated value":"10 hp","at 200/208 V rated value":"30 hp","at 220/230 V rated value":"40 hp","at 460/480 V rated value":"75 hp","at 575/600 V rated value":"100 hp","Locked-Rotor Current Peak":"6.5 A","Relative Humidity Minimum":"10 %","Holding Current Mean Value":"75 mA","Of Main Circuit Rated Value":"8 kV","Safety-Related Switching On":"No","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"23.7 W","at AC-2 at 400 V rated value":"55 kW","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"97 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"03/01/2017","Design Of The Surge Suppressor":"with varistor","Duration Of Inrush Current Peak":"50 µs","Locked-Rotor Current Mean Value":"3.2 A","at AWG cables for main contacts":"2x (10 ... 1/0), 1x (10 ... 2)","Duration Of Locked-Rotor Current":"150 ms","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"120 A","at AC-5b up to 400 V rated value":"110 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 200A (690V,100kA), aM: 100A (690V,100kA), BS88: 160A (415V,80kA)","Without Load Current Share Typical":"3.5 W","closing power of magnet coil at DC":"76 W","holding power of magnet coil at DC":"2.7 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"7.9 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"1 960 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"1 502 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"1 095 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"707 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"562 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"50 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7d28fa7380658c541019ac8751bc4da6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629941&mlfb=3RT2047-1NB30-1AA0"},"ai":{"faq":[{"question":"What is a direct replacement or equivalent for 3RT2047-1NB30-1AA0?","answer":"The closest functional peer is the 3RT2036-1AC20-ZX95, which shares the same Size S3 frame and screw terminals. The key difference is coil voltage — the peer uses 24 V AC/DC, while this unit is 20-33 V DC. Match your control voltage before swapping."},{"question":"Where can I buy the Siemens 3RT2047-1NB30-1AA0 and what is the price?","answer":"This part is sourced to order. Availability and pricing are confirmed at quote time. Contact our sales team for a current RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2047-1NB30-1AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2047-1NB30-1AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}