{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2325-1AP00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2325-1AP00","canonicalUrl":"https://aoctrl.com/siemens/3RT2325-1AP00","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2325-1AP00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS contactor, Size S0, 3RT2325-1AP00, 24 V AC coil, screw-type terminals, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"## Siemens SIRIUS 3RT2325-1AP00 — Size S0 Contactor, 24 V AC Coil The Siemens SIRIUS 3RT2325-1AP00 is a Size S0 contactor with a 24 V AC, 50 Hz coil rated at 230 V. It mounts via screw or snap-on onto 35 mm DIN rail per EN 60715, with a +/-180° rotation and +/-22.5° tilt allowance on vertical surfaces. The screw-type magnet coil termination and auxiliary switch are integrated, with one instantaneous contact. The arcing time of 10–10 ms is consistent for AC switching — expect clean break on resistive and light inductive loads. The 10 mm clearance upwards, downwards, and forwards plus 6 mm sideways is the minimum air gap for heat dissipation and arc flash — don't crowd it against busbars or other contactors. The 3RT2325-1AP00 accepts solid conductors up to 2x (0.5–1.5 mm²) and 2x (0.75–2.5 mm²), and stranded up to 1–10 mm². The 60 mm width and 85 mm height fit standard S0 footprint on DIN rail. Depth is 97 mm — check your enclosure depth if you're mounting a row of these with wiring ducts.","metaTitle":"Siemens SIRIUS 3RT2325-1AP00 Contactor, Size S0, 24V AC Coil","metaDescription":"Siemens SIRIUS 3RT2325-1AP00 Size S0 contactor, 24V AC coil, screw terminals, DIN rail mount. Sourced to order. Request RFQ for current pricing and availability.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"97 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"60 mm","at AC":"4 ... 16 ms","Height":"85 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","at 50 Hz":"0.25","Downwards":"10 mm","Attachable":"2","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Type Of Voltage":"AC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","For Main Contacts":"16 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"6 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"1","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC in hot operating state":"7.6 W","at AC-3 at 400 V rated value":"7.5 kW","at AC-4 at 400 V rated value":"7.5 kW","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","Product Function Bus Communication":"No","With Type Of Assignment 2 Required":"gG: 20 A (690 V, 100 kA)","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"1 000 1/h","With Type Of Coordination 1 Required":"gG: 63 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"1.9 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NO contacts for main contacts":"4","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"4","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (690 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","Of The Auxiliary And Control Circuit With Degree Of Pollution 3 Rated Value":"690 V","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$34.29","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b7f38e9f9d86e59b04eac68bfea90c40.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=217592&mlfb=3RT2325-1AP00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2325-1AP00/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT2325-1AP00 and get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm current pricing and availability — no stock or price figures are published here."},{"question":"What is the depth of 3RT2325-1AP00?","answer":"The depth is 97 mm, which is the dimension from the DIN rail mounting surface to the furthest point of the contactor body."},{"question":"What conductor sizes does 3RT2325-1AP00 accept?","answer":"Solid conductors: 2x (0.5–1.5 mm²) and 2x (0.75–2.5 mm²). Stranded: 1–10 mm²."},{"question":"Will 3RT2325-1AP00 drop into a panel designed for 3RT2024-1AL20-ZX95?","answer":"Both are Size S0 contactors on the same DIN rail footprint, so mechanical fit should match. However, verify coil voltage — the 3RT2325-1AP00 uses a 24 V AC coil, while the 3RT2024-1AL20-ZX95 may differ. Check terminal wiring and auxiliary contact configuration before swapping."},{"question":"What compliance documentation does Siemens provide for 3RT2325-1AP00?","answer":"The evidence does not list specific certifications (UL, CSA, CE, RoHS) for this order code. Standard Siemens SIRIUS contactors typically carry CE marking for the European market and may have UL/CSA listings — confirm with the manufacturer or your local Siemens office for the exact documentation package."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2325-1AP00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2325-1AP00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}