{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2325-2BM40-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2325-2BM40-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT2325-2BM40-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2325-2BM40-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS contactor, size S0, 3RT2325-2BM40-ZX95, 60 mm width, 107 mm depth, spring-type terminals, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"The contactor occupies 60 mm width and 107 mm depth, with 10 mm clearance upwards, forwards, and downwards, and 6 mm at the side — that's a compact footprint for a size S0 frame. ## Ratings that matter for the buyer The coil is DC-operated; the arcing time sits at 10 ms, and the operating time at DC is 15 to 18 ms — that means it switches fast enough for most motor-start and isolation duties. Main contact ratings span 24 VDC at 10 A up to 690 V at 1 A, with intermediate points at 48 V (2 A), 60 V (6 A), 110 V (1 A), 125 V (0.9 A), 220 V (0.3 A), 230 V (10 A), 400 V (3 A), 500 V (2 A), and 600 V (0.1 A). The 230 V at 10 A rating is the highest current on the list — that's the one to size against if you're switching a resistive load at that voltage. Main contacts accept solid conductors 2x (0.5 to 2.5 mm²) or stranded 1 to 10 mm², and the coil uses spring-type terminals — no screwdriver needed for the coil connection, which speeds up panel wiring.","metaTitle":"Siemens 3RT2325-2BM40-ZX95 SIRIUS Contactor, Size S0, 60 mm","metaDescription":"Siemens SIRIUS contactor 3RT2325-2BM40-ZX95, size S0, 60 mm width, 107 mm depth, spring-type terminals, screw and snap-on DIN rail mounting, current production, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"107 mm","Solid":"2x (0.5 ... 2.5 mm²)","Width":"60 mm","at DC":"15 ... 18 ms","Height":"102 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","Downwards":"10 mm","Attachable":"2","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","Rated Value":"220 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","Type Of Voltage":"DC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Full-Scale Value":"1.1","For Main Contacts":"18 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"6 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 500 V rated value":"2 A","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"1","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"spring-loaded terminals","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC in hot operating state":"7.6 W","at AC-3 at 400 V rated value":"7.5 kW","at AC-4 at 400 V rated value":"7.5 kW","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","Product Function Bus Communication":"No","With Type Of Assignment 2 Required":"gG: 20 A (690 V, 100 kA)","Without Load Current Share Typical":"5.9 W","closing power of magnet coil at DC":"5.9 W","holding power of magnet coil at DC":"5.9 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","operating frequency at AC-1 maximum":"1 000 1/h","With Type Of Coordination 1 Required":"gG: 63 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"1.9 W","for AWG cables for auxiliary contacts":"2x (20 ... 14)","number of NO contacts for main contacts":"4","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"4","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","Type Of Voltage Of The Control Supply Voltage":"DC","Limited To 1 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (690 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","Of The Auxiliary And Control Circuit With Degree Of Pollution 3 Rated Value":"690 V","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b7f38e9f9d86e59b04eac68bfea90c40.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=3959&mlfb=3RT2325-2BM40-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2325-2BM40-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What is 3RT2325-2BM40-ZX95's listed depth?","answer":"The depth is 107 mm, with a width of 60 mm and height of 102 mm — that's the physical envelope for panel layout."},{"question":"What wire sizes does the main contact accept?","answer":"Solid conductors: 2x (0.5 to 2.5 mm²); stranded: 1 to 10 mm². The coil uses spring-type terminals — no screwdriver needed there."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2325-2BM40-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2325-2BM40-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}