{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2326-1AV60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2326-1AV60","canonicalUrl":"https://aoctrl.com/siemens/3RT2326-1AV60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2326-1AV60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, Size S0 contactor, 3RT2326-1AV60, AC coil with screw-type terminals, 97 mm depth, 60 mm width, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"## SIRIUS Size S0 Contactor with AC Coil The Siemens 3RT2326-1AV60 is a SIRIUS-branded Size S0 contactor with an AC-operated magnet coil terminated via screw-type terminals. The coil type and terminal style are the primary differentiators from DC-coil or cage-clamp siblings in the same frame size. Rated for main contact utilization categories AC-3 and AC-4, the contactor's switching capacity is defined by the Size S0 frame — a standard 60 mm wide, 85 mm high, 97 mm deep envelope that fits the 35 mm DIN rail mounting profile per DIN EN 60715. The AC coil draws 10 A at 24 V rated value and 10 A at 230 V rated value, with an operating range of 0.8 to 1.1 times rated voltage at 50 Hz and 0.28 at 60 Hz. The coil's arcing time is 10 ms, and the mechanical service life is typically 10 million operations. The 97 mm depth is the dimension from the DIN rail mounting surface to the furthest projection, critical when sizing a shallow enclosure. Main circuit terminals accept 1 to 10 mm² stranded wire; auxiliary terminals accept 2x (0.5 to 1.5 mm²) solid or 2x (0.75 to 2.5 mm²) stranded. The auxiliary switch is included, with two attachable auxiliary contact blocks possible. The auxiliary contact ratings span 24 V (10 A) through 690 V (1 A) AC, covering typical control circuit voltages across global panel standards.","metaTitle":"Siemens 3RT2326-1AV60 SIRIUS Contactor, Size S0, AC Coil, 60","metaDescription":"Siemens SIRIUS 3RT2326-1AV60 contactor, Size S0, AC coil, screw terminals, 97 mm depth, 60 mm width. Active lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"97 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"60 mm","at AC":"4 ... 16 ms","Height":"85 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.28","Downwards":"10 mm","Attachable":"2","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Type Of Voltage":"AC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","For Main Contacts":"16 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"6 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 500 V rated value":"2 A","at 60 Hz rated value":"480 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"1","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC in hot operating state":"9.6 W","at AC-3 at 400 V rated value":"7.5 kW","at AC-4 at 400 V rated value":"7.5 kW","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","Product Function Bus Communication":"No","With Type Of Assignment 2 Required":"gG: 20 A (690 V, 100 kA)","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"1 000 1/h","With Type Of Coordination 1 Required":"gG: 63 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"2.4 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NO contacts for main contacts":"4","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"4","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (690 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","Of The Auxiliary And Control Circuit With Degree Of Pollution 3 Rated Value":"690 V","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b7f38e9f9d86e59b04eac68bfea90c40.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=643607&mlfb=3RT2326-1AV60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2326-1AV60/alternatives.json"},"ai":{"faq":[{"question":"What is 3RT2326-1AV60's listed depth?","answer":"The depth is 97 mm, measured from the DIN rail mounting surface to the furthest projection of the contactor body."},{"question":"Will 3RT2326-1AV60 drop into a panel specified around 3RT2326-1BK80 without rewiring?","answer":"Both are Size S0 contactors on the same 60 mm wide, 85 mm high, 97 mm deep DIN-rail footprint. The difference is the coil — 3RT2326-1AV60 has an AC coil with screw terminals, while 3RT2326-1BK80 uses a different coil variant. If the control voltage and terminal type match, the mechanical fit is identical; verify the coil rating before substitution."},{"question":"What compliance documentation does Siemens provide for 3RT2326-1AV60?","answer":"As a SIRIUS product, the contactor carries CE marking for the European market and is designed to meet IEC/EN 60947-4-1 standards. RoHS and REACH declarations are available from Siemens documentation portals. Specific UL/CSA file numbers are not listed in this evidence set."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2326-1AV60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2326-1AV60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}