{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2327-1AP00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2327-1AP00","canonicalUrl":"https://aoctrl.com/siemens/3RT2327-1AP00","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2327-1AP00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS contactor, S0 size, order code 3RT2327-1AP00, AC coil, screw-type terminals, 60 mm width, 97 mm depth, 85 mm height.","salesMarkdown":"## Siemens 3RT2327-1AP00 SIRIUS Contactor The contactor carries auxiliary switch capability, with a mechanical service life of 10 million operations typical — a figure that supports high-cycle applications like conveyor sorting or pump cycling where relay wear drives maintenance intervals. Wire termination accepts solid conductors: 2x (0.5 to 1.5 mm²) and 2x (0.75 to 2.5 mm²); stranded accepts 1 to 10 mm². The main contact screw terminals are sized for 16 to 8 AWG equivalents. These ranges cover typical motor-circuit wiring but do not allow aluminum conductor — stick to copper. At 97 mm depth, 60 mm width, and 85 mm height, the S0 footprint leaves room for adjacent power and control components on a 35 mm rail. Verify depth clearance against the enclosure door or back panel before committing the layout. ## Switching Ratings and Coil Data The AC coil is rated at 230 V at 50 Hz, drawing 0.25 A. Switching times: arcing time 10 to 10 ms, operate time 4 to 16 ms at AC. These figures matter for coordinating with upstream short-circuit protection and ensuring the contactor clears faults within the breaker's let-through window. Contact ratings across voltage levels: 10 A at 24 V and 230 V AC, 6 A at 60 V, 3 A at 400 V, 2 A at 48 V and 500 V, 1 A at 690 V, 0.9 A at 125 V, 0.3 A at 220 V, 0.1 A at 600 V.","metaTitle":"Siemens 3RT2327-1AP00 SIRIUS Contactor, S0 Size, 60 mm, AC C","metaDescription":"Siemens 3RT2327-1AP00 SIRIUS contactor, S0 size, 60 mm width, AC coil, screw terminals, DIN rail mount. Sourced to order against RFQ. Depth 97 mm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"97 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"60 mm","at AC":"4 ... 16 ms","Height":"85 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","at 50 Hz":"0.25","Downwards":"10 mm","Attachable":"2","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Type Of Voltage":"AC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","For Main Contacts":"16 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"6 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"1","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC in hot operating state":"12 W","at AC-3 at 400 V rated value":"7.5 kW","at AC-4 at 400 V rated value":"7.5 kW","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","Product Function Bus Communication":"No","With Type Of Assignment 2 Required":"gG: 20 A (690 V, 100 kA)","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"1 000 1/h","With Type Of Coordination 1 Required":"gG: 63 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"3 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NO contacts for main contacts":"4","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"4","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (690 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","Of The Auxiliary And Control Circuit With Degree Of Pollution 3 Rated Value":"690 V","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b7f38e9f9d86e59b04eac68bfea90c40.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=53235&mlfb=3RT2327-1AP00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2327-1AP00/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RT2327-1AP00?","answer":"The depth is 97 mm, with a width of 60 mm and height of 85 mm — the S0 frame size."},{"question":"What wire sizes does 3RT2327-1AP00 accept?","answer":"Solid conductors: 2x (0.5 to 1.5 mm²) and 2x (0.75 to 2.5 mm²). Stranded: 1 to 10 mm². Main contacts accept 16 to 8 AWG equivalents."},{"question":"Will 3RT2327-1AP00 drop into a panel specified around 3RT2326-1BK80 without rewiring?","answer":"Both are S0 frame contactors with the same mounting footprint and DIN-rail clip, so mechanical fit is identical. However, verify coil voltage and auxiliary contact configuration — the 3RT2327-1AP00 uses an AC coil; the 3RT2326-1BK80 may differ. Check the terminal assignments before assuming a drop-in swap."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2327-1AP00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2327-1AP00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}