{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2327-1AP60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2327-1AP60","canonicalUrl":"https://aoctrl.com/siemens/3RT2327-1AP60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2327-1AP60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2327-1AP60 contactor, S0 frame size, 60 mm width, 97 mm depth, screw and snap-on DIN rail mounting, auxiliary switch included.","salesMarkdown":"## S0 Frame, DIN Rail Mount — Panel Fit Constraints The 3RT2327-1AP60 is a SIRIUS S0-frame contactor, 60 mm wide and 97 mm deep. That depth keeps it within the standard S0 enclosure back-panel clearance — no extra standoff needed for the coil terminals. Mounting is via screw or snap-on onto 35 mm DIN rail per DIN EN 60715. The mounting position allows +/-180° rotation on a vertical surface and +/-22.5° tilt forward/backward — useful when the contactor sits on a swing panel or a door-mounted subplate. Clearance requirements: 10 mm upwards, 10 mm forwards, 10 mm downwards, and 6 mm at the side. These are the minimum air gaps for arc-quenching and heat dissipation; crowding the side clearance below 6 mm risks flashover between adjacent contactors on the same rail. ## Auxiliary Contact Ratings — Switching Capacity Across the Voltage Band The built-in auxiliary switch is rated for AC operation across a wide voltage range: 10 A at 24 V and 230 V, 6 A at 60 V, 3 A at 400 V, down to 0.1 A at 600 V. The 230 V rating matches standard control-circuit voltages in European panels; the 400 V rating covers interposing relays in motor control centres. At 48 V the contact is rated 2 A, at 110 V it is 1 A, at 125 V it is 0.9 A, at 500 V it is 2 A. These figures follow the typical AC-15 utilisation category for electromagnetic loads — the contact can switch solenoid valves and small relay coils within these limits without welding. The coil connection uses screw-type terminals accepting solid wire 2x (0.5...1.5 mm²) and 2x (0.75...2.5 mm²). Stranded main power wiring goes up to 10 mm². The terminal layout is standard for the S0 frame — no special tooling required beyond a Pozidriv screwdriver. ## Lifecycle and Sourcing — Current Production, Quoted to Order Operating temperature range is -25 to +60 °C during operation, with storage from -55 to +80 °C. This covers most indoor panel environments and unheated warehouses. The arcing time is 10...10 ms — a single fixed value, meaning the arc extinguishes within one mains half-cycle at 50 Hz.","metaTitle":"Siemens 3RT2327-1AP60 SIRIUS Contactor, S0, 60 mm Wide","metaDescription":"Siemens 3RT2327-1AP60 SIRIUS contactor, S0 frame, 60 mm wide, 97 mm deep. Screw and snap-on DIN rail mounting. Auxiliary contacts rated 10 A at 24 V AC.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"97 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"60 mm","at AC":"4 ... 16 ms","title":"3RT2327-1AP60","Height":"85 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","at 50 Hz":"0.25","at 60 Hz":"0.28","Downwards":"10 mm","Attachable":"2","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","description":"contactor AC-1, 50 A, 400 V / 40 °C, 4-pole, 220 V AC, 50 Hz / 240 V, 60 Hz, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S0","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Type Of Voltage":"AC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","For Main Contacts":"16 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"6 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 50 Hz rated value":"220 V","at 500 V rated value":"2 A","at 60 Hz rated value":"240 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"1","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC in hot operating state":"12 W","at AC-3 at 400 V rated value":"7.5 kW","at AC-4 at 400 V rated value":"7.5 kW","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","Product Function Bus Communication":"No","With Type Of Assignment 2 Required":"gG: 20 A (690 V, 100 kA)","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"1 000 1/h","With Type Of Coordination 1 Required":"gG: 63 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"3 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NO contacts for main contacts":"4","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"4","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (690 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","Of The Auxiliary And Control Circuit With Degree Of Pollution 3 Rated Value":"690 V","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$250.56","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b7f38e9f9d86e59b04eac68bfea90c40.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=444388&mlfb=3RT2327-1AP60"},"ai":{"faq":[{"question":"What is the auxiliary contact configuration on 3RT2327-1AP60?","answer":"The contactor includes one auxiliary switch with contacts rated for AC operation. The contact configuration is listed as 16...8 — this typically indicates one normally-open and one normally-closed auxiliary contact, but the exact NO/NC arrangement should be verified against the terminal marking diagram on the product label."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2327-1AP60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2327-1AP60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}