{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2327-2AP00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2327-2AP00","canonicalUrl":"https://aoctrl.com/siemens/3RT2327-2AP00","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2327-2AP00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2327-2AP00 contactor, Size S0, 230 V AC coil, 10 A at 24 V, spring-type terminals, screw and snap-on DIN rail mount.","salesMarkdown":"## SIRIUS 3RT2327-2AP00 Contactor — S0 Frame, 230 V AC Coil It switches main contacts rated for motor loads up to 10 A at 24 V and 10 A at 230 V, with a mechanical life of 10 million operations. The 10 A rating at 24 V and 230 V covers small motor, resistive, and general-purpose loads in control panels. The 10 million mechanical cycles mean this contactor is suited for high-cycling applications like conveyor indexing or packaging lines where the contactor cycles frequently. The spring-type terminals accept solid wire 2x (0.5...2.5 mm²) or stranded 1...10 mm² — no ferrules required for solid, but stranded conductors benefit from ferrules to prevent whiskering under the spring cage. The 60 mm wide, 102 mm tall, 97 mm deep S0 frame fits standard DIN-rail enclosures. The contactor accepts up to two auxiliary switch blocks.","metaTitle":"Siemens SIRIUS 3RT2327-2AP00 Contactor, Size S0, 230 V AC Co","metaDescription":"Siemens SIRIUS 3RT2327-2AP00 contactor, Size S0, 230 V AC coil, 10 A at 24 V. Spring-type terminals, screw and snap-on DIN rail mount. Current lifecycle stage. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"97 mm","Solid":"2x (0.5 ... 2.5 mm²)","Width":"60 mm","at AC":"4 ... 16 ms","Height":"102 mm","Upwards":"10 mm","Forwards":"10 mm","Stranded":"1 ... 10 mm²","at 50 Hz":"0.25","Downwards":"10 mm","Attachable":"2","Arcing Time":"10 ... 10 ms","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","Type Of Voltage":"AC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","For Main Contacts":"18 ... 8","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"6 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"1","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"spring-loaded terminals","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC in hot operating state":"12 W","at AC-3 at 400 V rated value":"7.5 kW","at AC-4 at 400 V rated value":"7.5 kW","Substance Prohibitance (Date)":"10/01/2009","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","Product Function Bus Communication":"No","With Type Of Assignment 2 Required":"gG: 20 A (690 V, 100 kA)","At Contactor For Auxiliary Contacts":"Spring-type terminals","operating frequency at AC-1 maximum":"1 000 1/h","With Type Of Coordination 1 Required":"gG: 63 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"3 W","for AWG cables for auxiliary contacts":"2x (20 ... 14)","number of NO contacts for main contacts":"4","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"4","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (690 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"10 mm²","Of The Auxiliary And Control Circuit With Degree Of Pollution 3 Rated Value":"690 V","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b7f38e9f9d86e59b04eac68bfea90c40.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=336531&mlfb=3RT2327-2AP00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2327-2AP00/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RT2327-2AP00?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time — no stock or price figures are published here."},{"question":"What is the closest functional second-source to 3RT2327-2AP00?","answer":"The 3RT2326-1BK80 is a Size S0 contactor but with a different coil voltage (24 V DC) and screw terminals. It will not drop into the same panel without rewiring the coil circuit and verifying terminal compatibility."},{"question":"What is the depth of 3RT2327-2AP00?","answer":"The depth is 97 mm."},{"question":"What solid wire sizes does the spring-type terminal accept?","answer":"The spring-type terminal accepts solid wire 2x (0.5...2.5 mm²)."},{"question":"Will 3RT2327-2AP00 drop into a panel specified around 3RT2326-1BK80 without rewiring?","answer":"No — the 3RT2327-2AP00 uses a 230 V AC coil and spring-type terminals, while the 3RT2326-1BK80 uses a 24 V DC coil and screw terminals. The coil circuit and terminal wiring differ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2327-2AP00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2327-2AP00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}