{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2336-1AB00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2336-1AB00","canonicalUrl":"https://aoctrl.com/siemens/3RT2336-1AB00","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2336-1AB00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2336-1AB00 contactor, S2 frame, 24 VAC 50 Hz coil, screw-type terminals, 1 N/O + 1 N/C main contacts, auxiliary switch included.","salesMarkdown":"The Siemens 3RT2336-1AB00 is a SIRIUS S2-frame contactor with a 24 VAC 50 Hz coil, screw-type coil terminals, and a 1 N/O + 1 N/C main contact configuration. It includes an auxiliary switch, which saves a separate add-on block for basic signal feedback. The S2 frame size positions it as a mid-range unit in the SIRIUS family, suited for motor loads and resistive switching in control panels up to roughly 7.5 kW at 400 V (AC-3 duty, typical for this frame). These are the minimum air gaps to maintain rated insulation; a panel builder can pack units tighter only if the side-by-side mounting allowance is used. The auxiliary switch is built-in and rated across a voltage range: 10 A at 24 V, 10 A at 230 V, 3 A at 400 V, 1 A at 690 V (all AC). These are the thermal current ratings for the auxiliary contacts — they define the maximum continuous current the auxiliary circuit can carry at each voltage level. For a 24 V control circuit, the 10 A rating is generous; at 690 V the 1 A limit reflects the reduced arc-quenching capability at higher voltage. The -40 °C low end is relevant for cold environments; the +70 °C high end is typical for enclosed panels with moderate heat rise. Switching times: closing time 10–18 ms AC, arcing time 10–20 ms. These are fast enough for most sequencing applications; the arcing time matters for coordination with upstream fuses or breakers in a short-circuit scenario. Wire termination: solid or stranded conductors 2x (0.5...1.5 mm²) and 2x (0.75...2.5 mm²) per terminal. The screw-type coil terminals accept the same range. This covers standard control wiring up to 2.5 mm²; larger power wiring for the main circuit would need a different contactor frame. Up to 2 auxiliary contact blocks can be attached to this contactor, expanding the signal feedback capability beyond the built-in switch.","metaTitle":"Siemens 3RT2336-1AB00 SIRIUS Contactor, S2 Frame, 24 VAC Coi","metaDescription":"Siemens SIRIUS 3RT2336-1AB00 contactor, S2 frame, 24 VAC 50 Hz coil, screw terminals, 1 N/O + 1 N/C main contacts, auxiliary switch included. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"130 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"75 mm","at AC":"10 ... 18 ms","title":"3RT2336-1AB00","Height":"114 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.37","Downwards":"10 mm","Attachable":"2","Arcing Time":"10 ... 20 ms","At The Side":"6 mm","description":"contactor AC-1, 60 A, 400 V / 40 °C, 4-pole, 24 V AC, 50 Hz, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S2","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Type Of Voltage":"AC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-40 ... +70 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","For Main Contacts":"18 ... 1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"6 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 50 Hz rated value":"24 V","at 500 V rated value":"2 A","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"1","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC in hot operating state":"12.8 W","Substance Prohibitance (Date)":"10/01/2014","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","Product Function Bus Communication":"No","With Type Of Assignment 2 Required":"gG: 63 A (690 V,100 kA)","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"700 1/h","With Type Of Coordination 1 Required":"gG: 160 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"3.2 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NO contacts for main contacts":"4","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"4","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","Finely Stranded Without Core End Processing":"0.5 ... 2.5 mm²","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (690 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"16 mm²","Of The Auxiliary And Control Circuit With Degree Of Pollution 3 Rated Value":"690 V","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ca192699cf31b1a6b3427c82809b93b4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=3957&mlfb=3RT2336-1AB00"},"ai":{"faq":[{"question":"What is the depth of the 3RT2336-1AB00?","answer":"The depth is 130 mm."},{"question":"What wire sizes does the 3RT2336-1AB00 accept?","answer":"The terminals accept solid or stranded conductors: 2x (0.5...1.5 mm²) and 2x (0.75...2.5 mm²) per terminal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2336-1AB00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2336-1AB00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}