{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2336-1AF00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2336-1AF00","canonicalUrl":"https://aoctrl.com/siemens/3RT2336-1AF00","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2336-1AF00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS contactor, S2 size, AC coil, screw-type terminals, 75 mm width, 130 mm depth, 114 mm height.","salesMarkdown":"## SIRIUS 3RT2336-1AF00 — S2 Contactor, AC Coil The contactor mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715, and its 75 mm width, 114 mm height, and 130 mm depth fit standard panel layouts with side-by-side mounting permitted. ## Clearance and Mounting Flexibility Forwards and upwards clearance is 10 mm each, downwards also 10 mm, and side clearance is 6 mm — these are the minimum free-air gaps around the contactor for heat dissipation and arc quenching. ## Switching Performance and Contact Ratings Main contacts are rated for 18 A to 1 A. The contactor's mechanical life is typically 10,000,000 operations. Arcing time is 10 to 20 ms, and AC switching time is 10 to 18 ms. One instantaneous auxiliary contact is included, and up to 2 additional auxiliary switches can be attached. ## Auxiliary Contact Ratings Across Voltages The auxiliary switch (present on this unit) carries rated currents that vary by voltage: 10 A at 24 V AC, 10 A at 230 V AC, 6 A at 60 V, 3 A at 400 V, 2 A at 48 V and 500 V, 1 A at 110 V and 690 V, 0.9 A at 125 V, 0.3 A at 220 V, and 0.1 A at 600 V. These ratings define the auxiliary contact's switching capability for control circuits, signal lamps, or PLC inputs at the respective system voltages. ## Environmental and Wiring Specs The main contact terminals accept solid or stranded conductors: 2x (0.5 to 1.5 mm²) and 2x (0.75 to 2.5 mm²). The coil terminals are screw-type, and the power factor at 50 Hz is 0.37.","metaTitle":"Siemens 3RT2336-1AF00 SIRIUS Contactor, S2 Size, AC Coil","metaDescription":"Siemens SIRIUS 3RT2336-1AF00 contactor, S2 size, AC coil, 75 mm width, 130 mm depth. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"130 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"75 mm","at AC":"10 ... 18 ms","title":"3RT2336-1AF00","Height":"114 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.37","Downwards":"10 mm","Attachable":"2","Arcing Time":"10 ... 20 ms","At The Side":"6 mm","description":"contactor AC-1, 60 A, 400 V / 40 °C, 4-pole, 110 V AC, 50 Hz, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S2","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Type Of Voltage":"AC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-40 ... +70 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","For Main Contacts":"18 ... 1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"6 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 500 V rated value":"2 A","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"1","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"6 kV","at AC in hot operating state":"12.8 W","Substance Prohibitance (Date)":"10/01/2014","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","Product Function Bus Communication":"No","With Type Of Assignment 2 Required":"gG: 63 A (690 V,100 kA)","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"700 1/h","With Type Of Coordination 1 Required":"gG: 160 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"3.2 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NO contacts for main contacts":"4","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"4","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","Finely Stranded Without Core End Processing":"0.5 ... 2.5 mm²","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","Type Of Voltage Of The Control Supply Voltage":"AC","Limited To 1 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (690 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"16 mm²","Of The Auxiliary And Control Circuit With Degree Of Pollution 3 Rated Value":"690 V","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ca192699cf31b1a6b3427c82809b93b4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=464048&mlfb=3RT2336-1AF00"},"ai":{"faq":[{"question":"What is the depth of 3RT2336-1AF00?","answer":"The listed depth is 130 mm, with a width of 75 mm and height of 114 mm."},{"question":"What conductor sizes does 3RT2336-1AF00 accept?","answer":"The main contacts accept solid or stranded conductors: 2x (0.5 to 1.5 mm²) and 2x (0.75 to 2.5 mm²)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2336-1AF00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2336-1AF00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}