{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2344-1NP30","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2344-1NP30","canonicalUrl":"https://aoctrl.com/siemens/3RT2344-1NP30","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2344-1NP30","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2344-1NP30 contactor, size S3, 175-280 V AC/DC coil, screw-type terminals, 96 mm width, 140 mm height, 152 mm depth, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"## S3 Frame Contactor with Wide-Range AC/DC Coil The 3RT2344-1NP30 is a SIRIUS contactor in the S3 frame size, designed for switching motor loads in control panels and industrial machinery. Its coil accepts 175–280 V AC or DC directly, eliminating the need for a separate coil voltage converter on mixed-supply panels. Mounting is flexible: screw-fixed or snap-on onto 35 mm DIN rail per DIN EN 60715, with the contactor body rotatable ±180° on a vertical surface and tiltable ±22.5° forward or backward — useful when panel layout forces an unconventional orientation. ## Wire Termination and Auxiliary Contact Capacity Main circuit terminals accept stranded wire from 6 mm² up to 70 mm², covering a wide range of motor feed sizes without needing lug adapters. The auxiliary circuit uses screw terminals sized for 2x (0.5–1.5 mm²) solid or 2x (0.75–2.5 mm²) stranded — typical for control wiring in a panel. The contactor ships with an auxiliary switch block (2-pole) already attached, saving a separate order and DIN slot. Its auxiliary contacts carry rated values from 10 A at 24 V down to 0.3 A at 220 V — check the specific switching voltage against your PLC input or relay load. ## Lifecycle and Sourcing Reality Operating temperature range is -25 to +60 °C, with storage from -55 to +80 °C, covering most indoor industrial environments without derating concerns. Mechanical life is rated at 10 million operations typical, and main contact electrical life ranges from 10,000 to 2,000,000 operations depending on switching current and voltage.","metaTitle":"Siemens 3RT2344-1NP30 SIRIUS Contactor, S3 Frame","metaDescription":"Siemens 3RT2344-1NP30 SIRIUS contactor, size S3, 175-280V AC/DC coil, screw terminals. Stranded 6-70mm² main circuit. Current lifecycle status.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"152 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"96 mm","at AC":"38 ... 57 ms","at DC":"38 ... 57 ms","Height":"140 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"6 ... 70 mm²","at 50 Hz":"3.5 VA","at 60 Hz":"3.5 VA","Downwards":"10 mm","Attachable":"2","Arcing Time":"10 ... 20 ms","At The Side":"10 mm","Rated Value":"175 ... 280 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Type Of Voltage":"AC/DC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Full-Scale Value":"1.1","For Main Contacts":"10 ... 2","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S3","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Inrush Current Peak":"65 A","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"6 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"175 ... 280 V","at 500 V rated value":"2 A","at 60 Hz rated value":"175 ... 280 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"1","Side-By-Side Mounting":"Yes","For Auxiliary Contacts":"20 ... 14","For Main Current Circuit":"screw-type terminals","Locked-Rotor Current Peak":"1.2 A","Relative Humidity Minimum":"10 %","Holding Current Mean Value":"10 mA","Of Main Circuit Rated Value":"8 kV","at AC in hot operating state":"29.2 W","Substance Prohibitance (Date)":"09/01/2017","Design Of The Surge Suppressor":"with varistor","Duration Of Inrush Current Peak":"5 µs","Locked-Rotor Current Mean Value":"0.44 A","Duration Of Locked-Rotor Current":"150 ms","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","Product Function Bus Communication":"No","With Type Of Assignment 2 Required":"gR: 250 A (690 V, 100 kA)","Without Load Current Share Typical":"2.7 W","closing power of magnet coil at DC":"76 W","holding power of magnet coil at DC":"2.7 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"650 1/h","With Type Of Coordination 1 Required":"gG: 250 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"7.3 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NO contacts for main contacts":"4","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"4","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (690 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"35 mm²","Of The Auxiliary And Control Circuit With Degree Of Pollution 3 Rated Value":"690 V","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/589d2506d1b6308a8f97adbcbc16094e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=630035&mlfb=3RT2344-1NP30","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2344-1NP30/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2344-1NP30","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2344-1NP30 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}