{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2446-1NF30","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2446-1NF30","canonicalUrl":"https://aoctrl.com/siemens/3RT2446-1NF30","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2446-1NF30","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2446-1NF30 contactor, S3 frame size, AC/DC coil 83...155 V, screw and snap-on 35 mm DIN rail mounting, 152 mm depth x 70 mm width x 140 mm height.","salesMarkdown":"## S3 frame contactor for motor switching in control panels The 3RT2446-1NF30: Its AC/DC coil accepts 83...155 V, covering 110 V and 120 V nominal control supplies without needing separate coil variants — a single part number simplifies BOM management across mixed-voltage installations. ## Panel fit and wiring capacity This lets the panel builder orient the contactor to fit cable entry or busbar routing without custom brackets. Dimensions are 152 mm depth x 70 mm width x 140 mm height. The main power circuit accepts stranded wire 6...70 mm², covering motor feed cables up to the S3 frame rating. An auxiliary switch is included, reducing external component count for feedback or interlock circuits.","metaTitle":"Siemens 3RT2446-1NF30 SIRIUS Contactor, S3 Frame","metaDescription":"Siemens 3RT2446-1NF30 SIRIUS contactor, S3 frame size, AC/DC coil 83-155 V, screw and snap-on DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"152 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"70 mm","at AC":"38 ... 57 ms","at DC":"38 ... 57 ms","Height":"140 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"6 ... 70 mm²","at 50 Hz":"3.5 VA","at 60 Hz":"3.5 VA","Downwards":"10 mm","Attachable":"2","Arcing Time":"10 ... 20 ms","At The Side":"10 mm","Rated Value":"83 ... 155 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Type Of Voltage":"AC/DC","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Full-Scale Value":"1.1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S3","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Inrush Current Peak":"1.5 A","Product Designation":"Contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"83 ... 155 V","at 500 V rated value":"2 A","at 60 Hz rated value":"83 ... 155 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Instantaneous Contact":"1","Side-By-Side Mounting":"Yes","For Main Current Circuit":"box terminal","Locked-Rotor Current Peak":"2.7 A","Relative Humidity Minimum":"10 %","Holding Current Mean Value":"15 mA","Of Main Circuit Rated Value":"8 kV","at AC in hot operating state":"29.4 W","Substance Prohibitance (Date)":"04/28/2017","Design Of The Surge Suppressor":"with varistor","Duration Of Inrush Current Peak":"50 µs","Locked-Rotor Current Mean Value":"1.1 A","Duration Of Locked-Rotor Current":"150 ms","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gR: 250 A (690 V, 100 kA)","Without Load Current Share Typical":"1.8 W","closing power of magnet coil at DC":"76 W","holding power of magnet coil at DC":"1.8 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-1 maximum":"650 1/h","With Type Of Coordination 1 Required":"gG: 250 A (690 V,100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"9.8 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Type Of Voltage For Main Current Circuit":"AC","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"50 mm²","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (230 V, 400 A)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b565132adc8ca4f5501331a77657e7cf.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=630072&mlfb=3RT2446-1NF30","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2446-1NF30/alternatives.json"},"ai":{"faq":[{"question":"What wire sizes does the main power circuit accept?","answer":"The main power terminals accept stranded wire from 6 mm² up to 70 mm²."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2446-1NF30","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2446-1NF30 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}