{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2535-1AD00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2535-1AD00","canonicalUrl":"https://aoctrl.com/siemens/3RT2535-1AD00","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2535-1AD00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2535-1AD00, size S2 contactor, 10 A at 24 V, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"The 10 A rating at 24 V is the auxiliary contact current for DC control circuits — this is the contactor's coil or auxiliary switch capacity, not the main pole current. For AC main circuits, the contactor carries 42 V at 50 Hz as its rated insulation voltage, meaning it's sized for low-voltage control rather than direct motor switching at 400 V. The size S2 frame (114 mm height, 75 mm width, 130 mm depth) is a mid-range footprint — larger than S0 but smaller than S3, fitting standard 600 mm wide enclosures with room for side-by-side mounting (allowed per spec). Auxiliary contacts are screw-type terminals accepting 2x 0.5–1.5 mm² or 2x 0.75–2.5 mm² solid/stranded wire — standard for panel wiring with ferrule or direct termination.","metaTitle":"Siemens 3RT2535-1AD00 SIRIUS Contactor, Size S2, 10 A at 24","metaDescription":"Siemens SIRIUS 3RT2535-1AD00 contactor, size S2, rated 10 A at 24 V. Screw and snap-on mounting on 35 mm DIN rail. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"130 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"75 mm","at AC":"10 ... 18 ms","Height":"114 mm","Upwards":"50 mm","Forwards":"0 mm","at 50 Hz":"0.37","Backwards":"0 mm","Downwards":"50 mm","Arcing Time":"10 ... 20 ms","At The Side":"10 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 200 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-40 ... +70 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1 A","at 50 Hz rated value":"42 V","at 500 V rated value":"2 A","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","Relative Humidity Minimum":"10 %","per NC contact rated value":"35 A","per NO contact rated value":"35 A","Of Main Circuit Rated Value":"6 kV","Substance Prohibitance (Date)":"10/01/2014","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 63A (690V, 100kA)","at 24 V per NC contact rated value":"55 A","at 24 V per NO contact rated value":"55 A","At Contactor For Auxiliary Contacts":"Screw-type terminals","at 110 V per NC contact rated value":"12.5 A","at 110 V per NO contact rated value":"25 A","at 220 V per NC contact rated value":"2.5 A","at 220 V per NO contact rated value":"5 A","at 230 V per NC contact rated value":"11 kW","at 230 V per NO contact rated value":"11 kW","at 400 V per NC contact rated value":"18.5 kW","at 400 V per NO contact rated value":"18.5 kW","at 440 V per NC contact rated value":"0.135 A","at 440 V per NO contact rated value":"0.27 A","With Type Of Coordination 1 Required":"gG: 125 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NC contacts for main contacts":"2","number of NO contacts for main contacts":"2","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"4","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","at ambient temperature 40 °C rated value":"60 A","at ambient temperature 60 °C rated value":"55 A","mirror contact according to IEC 60947-4-1":"Yes","apparent holding power of magnet coil at AC":"16 VA","apparent pick-up power of magnet coil at AC":"190 VA","Type Of Voltage Of The Control Supply Voltage":"AC","for 3-phase AC motor at 460/480 V rated value":"20 hp","Limited To 1 S Switching At Zero Current Maximum":"546 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"443 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"334 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"241 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"196 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Inductive Power Factor With Closing Power Of The Coil":"0.72","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.37","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 10 A","minimum cross-section in main circuit at maximum AC-1 rated value":"16 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","AWG number as coded connectable conductor cross section for main contacts":"18 ... 1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","power loss [W] at AC-3 at 400 V for rated value of the operational current per conductor":"4 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2b78e30a90020103238404e63b1d8379.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=366649&mlfb=3RT2535-1AD00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2535-1AD00/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions for panel layout?","answer":"Height 114 mm, width 75 mm, depth 130 mm. Side-by-side mounting is permitted with a 10 mm gap at the side. Forward and backward clearance is 0 mm, upward and downward clearance is 50 mm."},{"question":"What wire sizes does the screw terminal accept?","answer":"The main current circuit and auxiliary terminals accept 2x 0.5–1.5 mm² or 2x 0.75–2.5 mm² solid or stranded wire."},{"question":"Does 3RT2535-1AD00 drop into a panel specified for 3RT2027-1AF00?","answer":"Both are SIRIUS contactors on the 35 mm DIN rail standard, but the 3RT2535 is size S2 while the 3RT2027 series is typically smaller (size S0). Check the mounting footprint — the S2 is 75 mm wide versus S0's narrower width — so it may not fit without rail relocation or enclosure depth adjustment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2535-1AD00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2535-1AD00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}