{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2535-1NP30","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2535-1NP30","canonicalUrl":"https://aoctrl.com/siemens/3RT2535-1NP30","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2535-1NP30","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, size S2 contactor, 3RT2535-1NP30, 24 V rated 10 A, screw-type coil terminals, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"## SIRIUS S2 contactor for 24 VDC coil circuits The Siemens SIRIUS 3RT2535-1NP30 is a size S2 contactor with a 24 V rated coil drawing 10 A at rated value, designed for screw-type coil terminals and snap-on mounting onto 35 mm DIN rail per DIN EN 50022. Rated auxiliary contact current at 230 V is 6 A, at 400 V is 3 A, and at 440 V is 1 A — covering common control and small motor circuits in European panels. The contactor carries an auxiliary switch as standard, and its screw-type coil terminals accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire. ## Panel fit and mounting flexibility Dimensions: 75 mm wide, 114 mm high, 130 mm deep. Clearance requirements: 50 mm above and below, 10 mm to the side, 0 mm forward/backward for arc flash containment. The coil rated voltage is 175 to 280 V AC/DC, with a pick-up factor of 0.8 and a drop-out factor of 1.1. Maximum mechanical switching rate at AC-1 duty is 350 operations per hour. Typical mechanical life is 10,000,000 cycles. Inrush current peak is 25 A. Power factor at 50/60 Hz is 0.95 — near-unity, meaning minimal reactive load on the control transformer.","metaTitle":"Siemens 3RT2535-1NP30 SIRIUS Contactor, Size S2, 24V Coil","metaDescription":"Siemens SIRIUS 3RT2535-1NP30 contactor, size S2, 24V rated 10A, 3-pole, screw terminals, DIN rail mount. Sourced to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"130 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"75 mm","at AC":"30 ... 55 ms","at DC":"30 ... 55 ms","Height":"114 mm","Upwards":"50 mm","Forwards":"0 mm","at 50 Hz":"0.95","at 60 Hz":"0.95","Backwards":"0 mm","Downwards":"50 mm","Arcing Time":"10 ... 20 ms","At The Side":"10 mm","Rated Value":"175 ... 280 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"350 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-40 ... +70 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","Full-Scale Value":"1.1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Inrush Current Peak":"25 A","Product Designation":"contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1 A","at 50 Hz rated value":"175 ... 280 V","at 500 V rated value":"2 A","at 60 Hz rated value":"175 ... 280 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","Locked-Rotor Current Peak":"1.5 A","Relative Humidity Minimum":"10 %","Holding Current Mean Value":"10 mA","per NC contact rated value":"35 A","per NO contact rated value":"35 A","Of Main Circuit Rated Value":"6 kV","Substance Prohibitance (Date)":"10/01/2014","Design Of The Surge Suppressor":"with varistor","Duration Of Inrush Current Peak":"10 µs","Locked-Rotor Current Mean Value":"0.58 A","Duration Of Locked-Rotor Current":"230 ms","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","at DC at 24 V maximum permissible":"20 A","With Type Of Assignment 2 Required":"gG: 63A (690V, 100kA)","at 24 V per NC contact rated value":"55 A","at 24 V per NO contact rated value":"55 A","at AC at 230 V maximum permissible":"20 A","closing power of magnet coil at DC":"70 W","holding power of magnet coil at DC":"1.5 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","at 110 V per NC contact rated value":"12.5 A","at 110 V per NO contact rated value":"25 A","at 220 V per NC contact rated value":"2.5 A","at 220 V per NO contact rated value":"5 A","at 230 V per NC contact rated value":"11 kW","at 230 V per NO contact rated value":"11 kW","at 400 V per NC contact rated value":"18.5 kW","at 400 V per NO contact rated value":"18.5 kW","at 440 V per NC contact rated value":"0.135 A","at 440 V per NO contact rated value":"0.27 A","With Type Of Coordination 1 Required":"gG: 125 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"2","number of NO contacts for main contacts":"2","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"4","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","at ambient temperature 40 °C rated value":"60 A","at ambient temperature 60 °C rated value":"55 A","mirror contact according to IEC 60947-4-1":"Yes","apparent holding power of magnet coil at AC":"2.5 VA","apparent pick-up power of magnet coil at AC":"110 VA","Type Of Voltage Of The Control Supply Voltage":"AC/DC","for 3-phase AC motor at 460/480 V rated value":"20 hp","Limited To 1 S Switching At Zero Current Maximum":"546 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"443 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"334 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"241 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"196 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Inductive Power Factor With Closing Power Of The Coil":"0.72","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.95","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 10 A","minimum cross-section in main circuit at maximum AC-1 rated value":"16 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","AWG number as coded connectable conductor cross section for main contacts":"18 ... 1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","power loss [W] at AC-3 at 400 V for rated value of the operational current per conductor":"4 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5acbec323207f2565375da81341f7215.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=441120&mlfb=3RT2535-1NP30","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2535-1NP30/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of the 3RT2535-1NP30?","answer":"The depth is 130 mm, with a width of 75 mm and height of 114 mm."},{"question":"What wire sizes does the 3RT2535-1NP30 accept?","answer":"The screw-type terminals accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2535-1NP30","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2535-1NP30 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}