{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2536-1AP60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2536-1AP60","canonicalUrl":"https://aoctrl.com/siemens/3RT2536-1AP60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2536-1AP60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS contactor, 3RT2536-1AP60, size S2, 75 mm width, screw-type coil terminals, 10 A at 24 V rated value.","salesMarkdown":"That's a standard panel footprint — 75 mm wide, 114 mm tall, 130 mm deep — so it drops into most existing layouts without re-drilling the backplate. Coil terminals are screw-type, and the contactor carries an auxiliary switch block. The main contacts are rated 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V — figures that tell you this is a control-duty contactor, not a power-feed device. ## Clearance and Wiring Clearance requirements are tight: 0 mm forward and backward, 50 mm upward and downward, 10 mm at the sides. That means you can pack contactors side-by-side with no gap front-to-back, but you need breathing room above and below for wiring and heat dissipation. Solid wire sizes accepted are 2x (0.5 to 1.5 mm²) and 2x (0.75 to 2.5 mm²) — standard control wiring, nothing exotic. Operating time at AC is 10 to 18 ms, arcing time 10 to 20 ms. That's fast enough for most sequencing applications, but if you're coordinating with semiconductor outputs or fast PLC cycles, account for the arcing window in your timing budget.","metaTitle":"Siemens 3RT2536-1AP60 SIRIUS Contactor, Size S2, 75 mm","metaDescription":"Siemens 3RT2536-1AP60 SIRIUS contactor, size S2, 75 mm wide, screw-type terminals, 10 A at 24 V. Current lifecycle stage. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"130 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"75 mm","at AC":"10 ... 18 ms","Height":"114 mm","Upwards":"50 mm","Forwards":"0 mm","at 50 Hz":"0.36","at 60 Hz":"0.39","Backwards":"0 mm","Downwards":"50 mm","Arcing Time":"10 ... 20 ms","At The Side":"10 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"1 000 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-40 ... +70 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1 A","at 50 Hz rated value":"220 V","at 500 V rated value":"2 A","at 60 Hz rated value":"240 V","at 600 V rated value":"0.1 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","Relative Humidity Minimum":"10 %","per NC contact rated value":"41 A","per NO contact rated value":"41 A","Of Main Circuit Rated Value":"6 kV","Substance Prohibitance (Date)":"10/01/2014","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 80 A (690 V, 100 kA)","at 24 V per NC contact rated value":"55 A","at 24 V per NO contact rated value":"55 A","At Contactor For Auxiliary Contacts":"Screw-type terminals","at 110 V per NC contact rated value":"12.5 A","at 110 V per NO contact rated value":"25 A","at 220 V per NC contact rated value":"2.5 A","at 220 V per NO contact rated value":"5 A","at 230 V per NC contact rated value":"15 kW","at 230 V per NO contact rated value":"15 kW","at 400 V per NC contact rated value":"22 kW","at 400 V per NO contact rated value":"22 kW","at 440 V per NC contact rated value":"0.135 A","at 440 V per NO contact rated value":"0.27 A","With Type Of Coordination 1 Required":"gG: 160 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NC contacts for main contacts":"2","number of NO contacts for main contacts":"2","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"4","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","at ambient temperature 40 °C rated value":"70 A","at ambient temperature 60 °C rated value":"60 A","mirror contact according to IEC 60947-4-1":"Yes","apparent holding power of magnet coil at AC":"17.2 VA","apparent pick-up power of magnet coil at AC":"190 VA","Type Of Voltage Of The Control Supply Voltage":"AC","for 3-phase AC motor at 460/480 V rated value":"25 hp","Limited To 1 S Switching At Zero Current Maximum":"546 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"443 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"334 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"241 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"196 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / P600","Inductive Power Factor With Closing Power Of The Coil":"0.72","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.36","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 10 A","minimum cross-section in main circuit at maximum AC-1 rated value":"25 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","AWG number as coded connectable conductor cross section for main contacts":"18 ... 1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","power loss [W] at AC-3 at 400 V for rated value of the operational current per conductor":"4 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e37036a5a7f9f8576c3093d2ae00d357.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=696206&mlfb=3RT2536-1AP60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2536-1AP60/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions of 3RT2536-1AP60?","answer":"Width is 75 mm, height 114 mm, depth 130 mm. It mounts on 35 mm DIN rail per DIN EN 50022 with screw or snap-on fastening."},{"question":"What wire sizes does 3RT2536-1AP60 accept?","answer":"Solid wire: 2x (0.5 to 1.5 mm²) and 2x (0.75 to 2.5 mm²). Coil terminals are screw-type."},{"question":"Where can I buy 3RT2536-1AP60?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm offer."},{"question":"What is the operating temperature range for 3RT2536-1AP60?","answer":"Operating temperature is -40 to +70 °C; storage temperature is -55 to +80 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2536-1AP60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2536-1AP60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}