{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2627-1NF35","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2627-1NF35","canonicalUrl":"https://aoctrl.com/siemens/3RT2627-1NF35","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2627-1NF35","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT2627-1NF35 contactor relay, 95-130 V AC/DC coil, screw-type terminals, 45 mm width, 135 mm height, 165 mm depth, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"The Siemens 3RT2627-1NF35 is a SIRIUS contactor relay with a 95-130 V AC/DC coil, screw-type terminals, and a 45 mm width that fits standard 35 mm DIN rail per DIN EN 50022. It switches loads across a range of voltages: 6 A at 24 V, 6 A at 230 V, 3 A at 400 V, and 1 A at 690 V, with a maximum operating rate of 100 switching cycles per hour up to 600 V, dropping to 72 cycles per hour at 690 V. The coil holds across the 95-130 V range at 50/60 Hz, with a pickup ratio of 0.7 to 1.3 times rated value. ## Where it lives in the panel The 45 mm width means it takes up one standard 45 mm module slot in a control panel. Screw-type terminals accept solid conductors: 2x (0.5-1.5 mm²), 2x (0.75-2.5 mm²), or 2x 4 mm². Stranded conductors: 2x (1-2.5 mm²) or 2x (2.5-10 mm²). At 40 °C ambient, a single 10 mm² conductor is rated; at 60 °C, two 10 mm² conductors. The coil terminals are screw-type as well.","metaTitle":"Siemens 3RT2627-1NF35 Contactor Relay, 95-130V AC/DC Coil, 4","metaDescription":"Siemens 3RT2627-1NF35 contactor relay. 95-130V AC/DC coil, 45mm width, screw terminals, DIN rail mount. Active lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"165 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Width":"45 mm","at AC":"30 ... 50 ms","at DC":"30 ... 50 ms","Height":"135 mm","at 24 V":"6 A","at 60 V":"2 A","Stranded":"2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)","at 110 V":"1 A","at 125 V":"0.9 A","at 220 V":"0.3 A","at 230 V":"6 A","at 400 V":"3 A","at 50 Hz":"0.7 ... 1.3","at 60 Hz":"0.7 ... 1.3","at 690 V":"1 A","at 40 °C":"1x 10 mm²","at 60 °C":"2x 10 mm²","Attachable":"0","Arcing Time":"10 ... 10 ms","Rated Value":"95 ... 130 V","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Initial Value":"0.7","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Type Of Voltage":"AC/DC","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","Full-Scale Value":"1.3","at 230 V maximum":"100 1/h","at 240 V maximum":"100 1/h","at 400 V maximum":"100 1/h","at 480 V maximum":"100 1/h","at 500 V maximum":"100 1/h","at 600 V maximum":"100 1/h","at 690 V maximum":"72 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Inrush Current Peak":"15 A","Product Designation":"capacitor contactors","at 50 Hz rated value":"95 ... 130 V","at 60 Hz rated value":"95 ... 130 V","Instantaneous Contact":"1","For Main Current Circuit":"screw-type terminals","Locked-Rotor Current Peak":"0.19 A","Relative Humidity Minimum":"10 %","Holding Current Mean Value":"19 mA","Of Main Circuit Rated Value":"6 kV","Substance Prohibitance (Date)":"05/01/2014","For Grounded Parts At The Side":"10 mm","Duration Of Inrush Current Peak":"30 µs","Locked-Rotor Current Mean Value":"0.13 A","Duration Of Locked-Rotor Current":"180 ms","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"No","at AC at 230 V maximum permissible":"7 mA","closing power of magnet coil at DC":"10.2 W","holding power of magnet coil at DC":"1.3 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","With Side-By-Side Mounting At The Side":"10 mm","Electrical Endurance (Operating Cycles)":"200 000","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"0.00000001","mirror contact according to IEC 60947-4-1":"No","apparent holding power of magnet coil at AC":"1.8 VA","apparent pick-up power of magnet coil at AC":"12 VA","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"1","Type Of Voltage Of The Control Supply Voltage":"AC/DC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.98","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.79","Of The Contactor With Added Auxiliary Switch Block Typical":"3 000 000","operational current of auxiliary contacts at AC-12 maximum":"10 A","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","AWG number as coded connectable conductor cross section for main contacts":"16 ... 8","For Short-Circuit Protection Of The Main Circuit With Type Of Coordination 1 Required":"gG: 80 A (690 V, 50 kA)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/36dd2efac410d81a7399adb948b76e7c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=529388&mlfb=3RT2627-1NF35","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT2627-1NF35/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT2627-1NF35 and get a price?","answer":"This part is sourced to order against an RFQ through independent distribution channels. Submit an RFQ for current availability and pricing — confirmed at quote time."},{"question":"What are the key contact ratings for 3RT2627-1NF35?","answer":"It switches 6 A at 24 V and 230 V, 3 A at 400 V, 1 A at 690 V, with a maximum operating rate of 100 cycles per hour up to 600 V and 72 cycles per hour at 690 V."},{"question":"What coil voltage does 3RT2627-1NF35 use?","answer":"The coil is rated 95-130 V AC/DC at 50/60 Hz, with a pickup ratio of 0.7 to 1.3 times the rated value."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2627-1NF35","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2627-1NF35 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}