{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT2636-1NF35","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT2636-1NF35","canonicalUrl":"https://aoctrl.com/siemens/3RT2636-1NF35","factsUrl":"https://aoctrl.com/api/mcp/products/3RT2636-1NF35","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RT2636-1NF35 contactor, AC/DC coil 83-155 V, screw and snap-on 35 mm DIN rail mounting, 65 mm width, 114 mm height, 130 mm depth.","salesMarkdown":"The 3RT2636-1NF35: The coil accepts AC or DC control voltage across a 83...155 V range, which covers common 110-120 V control circuits without needing a separate coil variant. This simplifies BOM consolidation when your panel runs mixed AC and DC control power. ## Termination and wiring capacity Main power circuit terminals accept stranded conductors: 2x (10...35 mm²) or a single 1x (10...50 mm²). This covers typical motor feeder sizes up to 50 mm² for the line and load side, matching the conductor cross-section to the contactor's current rating without requiring a separate terminal adapter. The 65 mm width and 114 mm height fit a standard 65 mm-wide DIN-rail footprint, leaving room for adjacent overload relays and busbars in a typical motor starter row. Depth of 130 mm means the contactor protrudes 130 mm from the rail — check enclosure depth clearance before laying out the gland plate. ## Switching performance and duty cycle Arcing time is 10...20 ms, and the contactor can achieve up to 100 operating cycles per hour at 230-400 V. At higher voltages the maximum switching frequency drops — 60/h at 480 V, 55/h at 500 V, 40/h at 600 V, and 30/h at 690 V (-). This derating is driven by arc energy and contact wear; if your application cycles a motor at 690 V more than 30 times per hour, the contactor will exceed its rated electrical life. This covers most panel orientations except horizontal rail mounting — the contactor must be on a vertical plane for proper arc extinction.","metaTitle":"Siemens 3RT2636-1NF35 Contactor, AC/DC Coil 83-155 V","metaDescription":"Siemens 3RT2636-1NF35 contactor with AC/DC coil rated 83-155 V. Screw and snap-on mounting on 35 mm DIN rail. Active production, quoted to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"130 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Width":"65 mm","at AC":"30 ... 55 ms","at DC":"30 ... 55 ms","title":"3RT2636-1NF35","Height":"114 mm","at 24 V":"6 A","at 60 V":"2 A","Stranded":"2x (10 ... 35 mm²), 1x (10 ... 50 mm²)","at 110 V":"1 A","at 125 V":"0.9 A","at 220 V":"0.3 A","at 230 V":"6 A","at 400 V":"3 A","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.8 ... 1.1","at 690 V":"0 A","at 40 °C":"1x 35 mm²","at 60 °C":"1x 50 mm²","Attachable":"1","Arcing Time":"10 ... 20 ms","Rated Value":"83 ... 155 V","description":"capacitor contactor, AC-6b 50 kVAr, / 400 V, 3-pole, 83-155 V AC/DC, 50/60 Hz, with integrated varistor, auxiliary contacts: 2 NC, screw terminal, size: S2","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Type Of Voltage":"AC/DC","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","Full-Scale Value":"1.1","at 230 V maximum":"100 1/h","at 240 V maximum":"100 1/h","at 400 V maximum":"100 1/h","at 480 V maximum":"60 1/h","at 500 V maximum":"55 1/h","at 600 V maximum":"40 1/h","at 690 V maximum":"30 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Inrush Current Peak":"12 A","Product Designation":"capacitor contactors","at 50 Hz rated value":"83 ... 155 V","at 60 Hz rated value":"83 ... 155 V","Instantaneous Contact":"0","For Main Current Circuit":"screw-type terminals","Locked-Rotor Current Peak":"3.1 A","Relative Humidity Minimum":"10 %","Holding Current Mean Value":"22 mA","Of Main Circuit Rated Value":"6 kV","Substance Prohibitance (Date)":"05/01/2014","For Grounded Parts At The Side":"10 mm","Duration Of Inrush Current Peak":"20 µs","Locked-Rotor Current Mean Value":"1.3 A","Duration Of Locked-Rotor Current":"230 ms","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","closing power of magnet coil at DC":"70 W","holding power of magnet coil at DC":"1.5 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","With Side-By-Side Mounting At The Side":"10 mm","Electrical Endurance (Operating Cycles)":"200 000","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"0.00000001","mirror contact according to IEC 60947-4-1":"No","apparent holding power of magnet coil at AC":"2.5 VA","apparent pick-up power of magnet coil at AC":"110 VA","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"0","Type Of Voltage Of The Control Supply Voltage":"AC/DC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.95","Of Main Circuit With Degree Of Pollution 3 Rated Value":"690 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.95","Of The Contactor With Added Auxiliary Switch Block Typical":"3 000 000","operational current of auxiliary contacts at AC-12 maximum":"10 A","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","AWG number as coded connectable conductor cross section for main contacts":"18 ... 0","For Short-Circuit Protection Of The Main Circuit With Type Of Coordination 1 Required":"gG: 160 A (690 V, 50 kA)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$220.98","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f0b961dea622cd6f16465848ba70b4b7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=366580&mlfb=3RT2636-1NF35"},"ai":{"faq":[{"question":"How can I order the 3RT2636-1NF35 or get a price?","answer":"The 3RT2636-1NF35 is an active-production part sourced through independent distribution. No stock-holding or same-day-ship claim is made — lead time depends on the supplier's inventory at the moment of quotation."},{"question":"What wire sizes does the 3RT2636-1NF35 accept on the main power terminals?","answer":"The main power terminals accept stranded conductors: 2x (10...35 mm²) or a single 1x (10...50 mm²). All terminals are screw-type."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT2636-1NF35","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT2636-1NF35 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}