{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT5065-6AV36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT5065-6AV36","canonicalUrl":"https://aoctrl.com/siemens/3RT5065-6AV36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT5065-6AV36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S10, 3RT5065-6AV36, 197 kW at 400 V 60 °C, screw-type terminals, varistor surge suppressor.","salesMarkdown":"It carries a rated insulation voltage of 1,000 V and delivers 197 kW at 400 V at 60 °C — the rating that governs motor sizing for a 400 V line. The contactor uses screw-type terminals for main circuit wiring and includes a built-in varistor surge suppressor across the coil. The headline power rating is 197 kW at 400 V at 60 °C, which is the figure to use when sizing for a 400 V three-phase motor on a conveyor, pump, or fan. At 230 V the same contactor delivers 113 kW at 60 °C. The mechanical endurance is 10 million cycles typical, so it outlasts most electromechanical loads in standard duty. Switching frequency limits vary by duty class: AC-1 (resistive) allows up to 800 operations per hour, AC-3 (squirrel-cage motor start/run) allows 700 per hour, and AC-4 (plugging/inching) drops to 130 per hour. The coil draws 6 A at 24 V rated value, 1 A at 110 V, and 0.3 A at 220 V — useful for control transformer sizing. The contactor measures 210 mm high, 145 mm wide, and 202 mm deep. It mounts via screw fixing and allows side-by-side mounting without derating. Minimum conductor cross-section is 185 mm² at both 40 °C and 60 °C.","metaTitle":"Siemens 3RT5065-6AV36 SIRIUS Power Contactor, S10, 197 kW at","metaDescription":"Siemens 3RT5065-6AV36 SIRIUS power contactor, Size S10, rated 197 kW at 400 V 60 °C. Screw terminals, varistor suppressor. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"202 mm","Width":"145 mm","at AC":"2 000 1/h","at DC":"2 000 1/h","title":"3RT5065-6AV36","Height":"210 mm","at 50 Hz":"0.9","at 60 Hz":"0.9","Rated Value":"380 ... 420 V","description":"Contactor 380...420 V AC/DC AC3 132 kW 400 V AC (50...60 Hz) / DC operation auxiliary contacts 2 NO + 2 NC, 3-pole, size S10 bar connections conventional operating mechan. screw terminal","During Storage":"-55 ... +80 °C","at AC-1 maximum":"800 1/h","at AC-3 maximum":"700 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","at AC-3e maximum":"700 1/h","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S10","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Power contactor","at 24 V rated value":"6 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"380 ... 420 V","at 60 Hz rated value":"380 ... 420 V","at 690 V rated value":"102 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-3e rated value maximum":"1 000 V","Substance Prohibitance (Date)":"03/01/2017","at 40 °C minimum permissible":"185 mm²","at 60 °C minimum permissible":"185 mm²","Design Of The Surge Suppressor":"with varistor","Insulation Voltage Rated Value":"1 000 V","at 230 V at 60 °C rated value":"113 kW","at 400 V at 60 °C rated value":"197 kW","at 690 V at 60 °C rated value":"340 kW","at AWG cables for main contacts":"2/0 ... 500 kcmil","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"fuse gL/gG: 400 A","closing power of magnet coil at DC":"650 W","holding power of magnet coil at DC":"7.4 W","Surge Voltage Resistance Rated Value":"8 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 500 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","at ambient temperature 40 °C rated value":"330 A","at ambient temperature 60 °C rated value":"300 A","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/89900494e9db0f315b0f181f94c944ec.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=580295&mlfb=3RT5065-6AV36"},"ai":{"faq":[{"question":"Where can I buy 3RT5065-6AV36 and how do I get a price?","answer":"The contactor is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ to confirm current availability and pricing at quote time."},{"question":"What are the key power ratings for 3RT5065-6AV36?","answer":"At 400 V at 60 °C it delivers 197 kW; at 230 V at 60 °C it delivers 113 kW. The rated insulation voltage is 1,000 V."},{"question":"What compliance documentation does this brand provide for 3RT5065-6AV36?","answer":"The substance prohibitance date of 03/01/2017 indicates RoHS compliance. The contactor carries pollution degree 3 rating per IEC 60947-1 standards."},{"question":"Will 3RT5065-6AV36 drop into a panel specified around 3RT5065-6AP36 without rewiring?","answer":"Both are Size S10 contactors with the same 210 x 145 x 202 mm footprint and screw-type terminals, so mechanical fit is identical. The difference is in the coil voltage variant — verify the coil rating matches your control voltage before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT5065-6AV36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT5065-6AV36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}