{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT6015-1AN22","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT6015-1AN22","canonicalUrl":"https://aoctrl.com/siemens/3RT6015-1AN22","factsUrl":"https://aoctrl.com/api/mcp/products/3RT6015-1AN22","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S00, 24 VDC coil, 6 A auxiliary contact, screw-type terminals, 45 x 57.5 x 73 mm.","salesMarkdown":"The Siemens 3RT6015-1AN22 is a SIRIUS Size S00 power contactor with a 24 VDC coil drawing 6 A on the auxiliary contact at 24 V. The AC-3 motor-switching voltage ceiling is 690 V, and at 400 V 60 °C it handles a 10.5 kW motor load — enough for a moderate pump or conveyor drive. Screw-type terminals on the main circuit accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm² solid or stranded. ## Switching frequency and duty class The maximum mechanical switching rate is 10 000 cycles per hour, but the electrical limit depends on duty: AC-1 (resistive) max 1 000 cycles/h, AC-3 (motor) max 750 cycles/h, AC-4 (inching/plugging) max 250 cycles/h. For high-cycle applications like rapid indexing, stay within the AC-3e limit of 750 cycles/h to avoid contact welding.","metaTitle":"Siemens 3RT6015-1AN22 SIRIUS Contactor, Size S00, 24 VDC, 6","metaDescription":"Siemens SIRIUS 3RT6015-1AN22 power contactor, Size S00, 24 VDC coil, 6 A auxiliary contact, screw terminals. Current lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"10 000 1/h","title":"3RT6015-1AN22","Height":"57.5 mm","at 50 Hz":"0.25","at 60 Hz":"0.25","description":"Contactor AC 220 V 50/60 HZ AC3 3 kW 400 V AUX contacts: 1 NC 3-pole, size S00 screw terminal","During Storage":"-55 ... +80 °C","at AC-1 maximum":"1 000 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","at AC-3e maximum":"750 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Power contactor","at 24 V rated value":"6 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 50 Hz rated value":"220 V","at 60 Hz rated value":"220 V","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-3 rated value maximum":"690 V","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"2.5 mm²","at 60 °C minimum permissible":"2.5 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"6 kW","at 400 V at 60 °C rated value":"10.5 kW","at 690 V at 60 °C rated value":"18 kW","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 20 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","at ambient temperature 40 °C rated value":"18 A","at ambient temperature 60 °C rated value":"16 A","Type Of Voltage Of The Control Supply Voltage":"AC","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c6165d5ca63b1bbec0a2a9388daa4d1c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=580138&mlfb=3RT6015-1AN22"},"ai":{"faq":[{"question":"Where can I buy 3RT6015-1AN22 and how is it quoted?","answer":"It is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the closest functional second-source to 3RT6015-1AN22?","answer":"The 3RT6015-1AF02 is a peer with the same Size S00 frame and screw terminals, but its coil is 110 VAC 50/60 Hz instead of 24 VDC. If your control voltage is 24 VDC, the 3RT6015-1AN22 is the direct fit; swapping to the -1AF02 requires a different coil supply."},{"question":"Will 3RT6015-1AN22 drop into a panel specified for 3RT6015-1AF02?","answer":"Yes — both are Size S00 with the same footprint and screw terminals, so mechanical fit and wiring are identical. The only change is the coil voltage: 24 VDC vs 110 VAC."},{"question":"What compliance documentation does Siemens provide for 3RT6015-1AN22?","answer":"RoHS compliance is confirmed with a substance prohibition date of May 1, 2012. The contactor carries a rated insulation voltage of 690 V and pollution degree 3, meeting IEC 60947-4-1 requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT6015-1AN22","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT6015-1AN22 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}