{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT6016-1AF02","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT6016-1AF02","canonicalUrl":"https://aoctrl.com/siemens/3RT6016-1AF02","factsUrl":"https://aoctrl.com/api/mcp/products/3RT6016-1AF02","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S00 power contactor, 3RT6016-1AF02, screw-type terminals, 7.5 kW at 230 V / 13 kW at 400 V at 60 °C, 690 V insulation voltage, DIN-rail mount.","salesMarkdown":"## S00 frame, screw terminals, 45 mm wide It snaps onto 35 mm DIN rail per DIN EN 50022 and measures 45 mm wide by 57.5 mm high by 73 mm deep — a compact footprint that leaves room on the rail for auxiliary blocks or an overload relay. Rated insulation voltage is 690 V, and at 60 °C ambient it delivers 7.5 kW at 230 V, 13 kW at 400 V, and 22 kW at 690 V — the numbers that matter when sizing for a motor load in a warm panel. ## Mounting and wiring flexibility Screw terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm² solid or stranded copper. Minimum wire size at 40 °C is 4 mm²; at 60 °C it's 2.5 mm² — that derating tells you the terminal temperature rise under full load. Mechanical life is 30 million operating cycles typical. Switching frequency maxes out at 10,000 operations per hour for general use, with AC-3 duty limited to 750 ops/h and AC-4 to 250 ops/h — the AC-4 figure is the one to watch if you're doing plugging or inching.","metaTitle":"Siemens 3RT6016-1AF02 SIRIUS S00 Power Contactor, 7.5 kW at","metaDescription":"Siemens 3RT6016-1AF02 SIRIUS S00 power contactor, 7.5 kW at 230 V / 13 kW at 400 V (60 °C). Screw terminals, DIN-rail mount. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"10 000 1/h","Height":"57.5 mm","at 50 Hz":"0.25","at 60 Hz":"0.25","During Storage":"-55 ... +80 °C","at AC-1 maximum":"1 000 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","at AC-3e maximum":"750 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Power contactor","at 24 V rated value":"6 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 60 Hz rated value":"110 V","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-3 rated value maximum":"690 V","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"4 mm²","at 60 °C minimum permissible":"2.5 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"7.5 kW","at 400 V at 60 °C rated value":"13 kW","at 690 V at 60 °C rated value":"22 kW","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 20 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","at ambient temperature 40 °C rated value":"22 A","at ambient temperature 60 °C rated value":"20 A","Type Of Voltage Of The Control Supply Voltage":"AC","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/72ccfd1a73c997e9c3cac8706688aaae.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=579880&mlfb=3RT6016-1AF02","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT6016-1AF02/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional alternative to 3RT6016-1AF02?","answer":"The 3RT6017-1KF42 is a higher-rated S00 contactor in the same SIRIUS family, but it uses a different coil voltage and terminal arrangement. The 3RT6016-1AF02 has screw terminals; the 3RT6017-1KF42 uses cage-clamp terminals. They share the same 45 mm width and DIN-rail mounting, so a panel laid out for one can physically accept the other, but the coil and wiring differences mean you'd need to verify the control circuit and re-terminate."},{"question":"Where can I buy 3RT6016-1AF02?","answer":"This part is sourced and quoted to order through independent distribution. Availability and current pricing are confirmed at quote time against an RFQ."},{"question":"What compliance documentation does Siemens provide for 3RT6016-1AF02?","answer":"The part carries a RoHS compliance date of May 1, 2012. As a SIRIUS contactor it is designed to meet IEC/EN 60947-4-1 and UL 508 standards for motor-controller applications. Declaration of conformity and the CE mark are standard with the brand."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT6016-1AF02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT6016-1AF02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}