{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT6016-1BF41","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT6016-1BF41","canonicalUrl":"https://aoctrl.com/siemens/3RT6016-1BF41","factsUrl":"https://aoctrl.com/api/mcp/products/3RT6016-1BF41","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S00 power contactor, 3RT6016-1BF41, 110 V AC coil, 13 kW at 400 V AC-3, screw terminals, snap-on DIN rail.","salesMarkdown":"## SIRIUS S00 power contactor, 110 V coil, screw terminals The Siemens SIRIUS 3RT6016-1BF41 is a size S00 power contactor with a 110 V AC coil, rated for AC-3 switching up to 690 V. It delivers 13 kW at 400 V and 22 kW at 690 V (both at 60 °C), making it a fit for motor loads like pumps, fans, and conveyors in a standard 400 V three-phase panel. Main and control circuits use screw terminals; the main terminals accept 2x (0.5 to 2.5 mm²) or 2x 4 mm², and the auxiliary switch can be added later via the product extension slot. ## Switching ratings and thermal limits At 60 °C ambient, the motor ratings are 7.5 kW at 230 V, 13 kW at 400 V, and 22 kW at 690 V — these are the numbers to use for sizing, not the 40 °C table. For resistive loads (AC-1), the maximum rate is 1 000 cycles per hour; for AC-4 (plugging/reversing), it drops to 250 cycles per hour. The coil hold-in is rated for 110 V, but the contactor also lists ratings at 220 V (0.3 A) and 230 V (10 A) for auxiliary circuit use — check the control voltage match before wiring. The substance prohibition date of 05/01/2012 aligns with RoHS and REACH compliance — documentation is standard with the shipment.","metaTitle":"Siemens 3RT6016-1BF41 SIRIUS Power Contactor, 110 V Coil, 13","metaDescription":"Siemens SIRIUS 3RT6016-1BF41 power contactor, size S00, 110 V AC coil, 13 kW at 400 V AC-3, screw terminals, snap-on DIN rail. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at DC":"10 000 1/h","Height":"57.5 mm","Rated Value":"110 V","During Storage":"-55 ... +80 °C","at AC-1 maximum":"1 000 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","at AC-3e maximum":"750 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Power contactor","at 24 V rated value":"6 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-3 rated value maximum":"690 V","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"4 mm²","at 60 °C minimum permissible":"2.5 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"7.5 kW","at 400 V at 60 °C rated value":"13 kW","at 690 V at 60 °C rated value":"22 kW","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 20 A","closing power of magnet coil at DC":"4 W","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","at ambient temperature 40 °C rated value":"22 A","at ambient temperature 60 °C rated value":"20 A","Type Of Voltage Of The Control Supply Voltage":"DC","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dbf20e327b90f7d08395d544fc919ee0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=579894&mlfb=3RT6016-1BF41","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT6016-1BF41/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT6016-1BF41?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the closest functional second-source for 3RT6016-1BF41?","answer":"The 3RT6017-1KF42 is a size S00 contactor with a 24 V DC coil — same footprint and screw terminals, but the coil voltage differs. For a 110 V AC coil, the 3RT6016-1BF41 is the direct fit; swapping to the 3RT6017-1KF42 requires a control transformer change."},{"question":"Will 3RT6016-1BF41 drop into a panel specified around 3RT6017-1KF42 without rewiring?","answer":"Yes, the physical dimensions (45 mm width, 73 mm depth, 57.5 mm height) and DIN rail mounting are identical, so it fits the same panel cutout. The wiring difference is the coil voltage — 110 V AC vs 24 V DC — so the control circuit must be re-terminated."},{"question":"What is the depth of 3RT6016-1BF41?","answer":"The depth is 73 mm."},{"question":"What compliance documentation does Siemens provide for 3RT6016-1BF41?","answer":"The part carries a substance prohibition date of 05/01/2012, consistent with RoHS and REACH compliance. Standard documentation includes a declaration of conformity and material declaration — available with the shipment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT6016-1BF41","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT6016-1BF41 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}