{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT6017-1AH01","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT6017-1AH01","canonicalUrl":"https://aoctrl.com/siemens/3RT6017-1AH01","factsUrl":"https://aoctrl.com/api/mcp/products/3RT6017-1AH01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT6017-1AH01, size S00, screw-type terminals, 7.5 kW at 230 V (60°C), 13 kW at 400 V (60°C), 22 kW at 690 V (60°C), AC-3 rated 690 V max, 45 x 57.5 x 73 mm.","salesMarkdown":"It's rated for AC-3 duty up to 690 V, with motor output ratings of 7.5 kW at 230 V, 13 kW at 400 V, and 22 kW at 690 V — all at 60 °C ambient, so no derating headache in a warm enclosure. Auxiliary contact ratings cover the usual control voltages: 6 A at 24 V, 10 A at 230 V, 3 A at 400 V, 1 A at 690 V. RoHS compliance date is noted as May 1, 2012, so it meets the EU substance restrictions that matter for CE marking. No UL or CSA marks appear in the spec record, but the SIRIUS line typically carries them — verify the specific nameplate if your panel requires a listed device. Size S00 footprint: 45 mm wide, 57.5 mm tall, 73 mm deep. Terminal capacity: accepts 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm² solid or stranded. Minimum cross-section at 40 °C is 4 mm², at 60 °C it's 2.5 mm² — that's the thermal derating for the power path, not a wiring restriction. ## How it compares to a sibling The closest functional peer in the SIRIUS line is the 3RT1015-1AG61. Both are size S00 power contactors with screw terminals and similar AC-3 motor ratings. The 3RT6017-1AH01 is the standard-duty variant; the 3RT1015-1AG61 is the higher-performance version with a wider coil voltage range and slightly different auxiliary contact configuration. If your panel was wired for the 3RT1015-1AG61, the 3RT6017-1AH01 will drop into the same DIN rail footprint and same terminal pattern — no rewiring needed for the power circuit. The difference is in the coil pickup and dropout characteristics, so verify the control voltage matches your PLC output.","metaTitle":"Siemens 3RT6017-1AH01 SIRIUS Power Contactor, Size S00, 7.5","metaDescription":"Siemens 3RT6017-1AH01 SIRIUS power contactor, size S00, screw terminals, 7.5 kW at 230 V 60°C, 13 kW at 400 V. Current lifecycle stage. DIN rail mount. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"10 000 1/h","Height":"57.5 mm","at 50 Hz":"0.25","at 60 Hz":"0.25","During Storage":"-55 ... +80 °C","at AC-1 maximum":"1 000 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","at AC-3e maximum":"750 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Power contactor","at 24 V rated value":"6 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 50 Hz rated value":"48 V","at 60 Hz rated value":"48 V","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-3 rated value maximum":"690 V","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"4 mm²","at 60 °C minimum permissible":"2.5 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"7.5 kW","at 400 V at 60 °C rated value":"13 kW","at 690 V at 60 °C rated value":"22 kW","for AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 20 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A","operational current at AC-12 maximum":"10 A","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","at ambient temperature 40 °C rated value":"22 A","at ambient temperature 60 °C rated value":"20 A","Type Of Voltage Of The Control Supply Voltage":"AC","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c612433b5c106fff1d66f36ce458337d.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=579910&mlfb=3RT6017-1AH01","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT6017-1AH01/alternatives.json"},"ai":{"faq":[{"question":"What are the key motor ratings for this contactor?","answer":"At 60 °C ambient, it's rated for 7.5 kW at 230 V, 13 kW at 400 V, and 22 kW at 690 V. AC-3 maximum voltage is 690 V."},{"question":"Will the 3RT6017-1AH01 fit in a panel designed for the 3RT1015-1AG61?","answer":"Yes, both are size S00 with the same 45 mm width and DIN rail mounting. The terminal pattern is identical for the main circuit, so it's a drop-in replacement without rewiring. The coil characteristics differ slightly, so confirm your control voltage."},{"question":"What compliance documentation does this part have?","answer":"RoHS compliance is documented with a substance prohibitance date of May 1, 2012. CE marking is implied for the EU market. No UL or CSA marks are listed in the spec record, but the SIRIUS series typically carries them — check the nameplate on your unit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT6017-1AH01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT6017-1AH01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}