{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT6018-1AD02","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT6018-1AD02","canonicalUrl":"https://aoctrl.com/siemens/3RT6018-1AD02","factsUrl":"https://aoctrl.com/api/mcp/products/3RT6018-1AD02","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S00, 3RT6018-1AD02, screw-type terminals, 13 kW at 400 V 60 °C, 690 V insulation voltage, 45 mm width, current lifecycle.","salesMarkdown":"## Siemens 3RT6018-1AD02 — SIRIUS Size S00 Power Contactor Rated for AC-3 duty up to 690 V, the contactor handles motor loads at elevated ambient temperatures: 7.5 kW at 230 V 60 °C, 13 kW at 400 V 60 °C, and 22 kW at 690 V 60 °C. Main current circuit connections use screw-type terminals accepting 2x (0.5…1.5 mm²), 2x (0.75…2.5 mm²), or 2x 4 mm² solid or stranded conductors. Minimum permissible cross-section at 40 °C is 4 mm²; at 60 °C it's 2.5 mm² — factor this into wire sizing for the panel build. Side-by-side mounting is permitted, so no mandatory spacing gaps for thermal derating in a standard lineup. Dimensions: 57.5 mm height, 45 mm width, 73 mm depth. Substance prohibitance date is 05/01/2012, aligning with RoHS compliance.","metaTitle":"Siemens 3RT6018-1AD02 SIRIUS Power Contactor, Size S00, 13 k","metaDescription":"Siemens 3RT6018-1AD02 SIRIUS power contactor, Size S00, screw terminals, 13 kW at 400 V 60 °C, 690 V insulation. Current lifecycle. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"10 000 1/h","Height":"57.5 mm","at 50 Hz":"0.25","at 60 Hz":"0.25","During Storage":"-55 ... +80 °C","at AC-1 maximum":"1 000 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","at AC-3e maximum":"750 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Power contactor","at 24 V rated value":"6 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 50 Hz rated value":"42 V","at 60 Hz rated value":"42 V","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-3 rated value maximum":"690 V","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"4 mm²","at 60 °C minimum permissible":"2.5 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"7.5 kW","at 400 V at 60 °C rated value":"13 kW","at 690 V at 60 °C rated value":"22 kW","for AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 20 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A","operational current at AC-12 maximum":"10 A","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","at ambient temperature 40 °C rated value":"22 A","at ambient temperature 60 °C rated value":"20 A","Type Of Voltage Of The Control Supply Voltage":"AC","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a03479bef8890b0d1776cfaeb29cf3bb.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=723075&mlfb=3RT6018-1AD02","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT6018-1AD02/alternatives.json"},"ai":{"faq":[{"question":"What is 3RT6018-1AD02's motor power rating at 400 V?","answer":"At 400 V and 60 °C ambient, the contactor is rated for 13 kW motor load under AC-3 duty."},{"question":"What compliance documentation does Siemens provide for 3RT6018-1AD02?","answer":"The part has a substance prohibitance date of 05/01/2012 (RoHS compliance) and is rated for pollution degree 3. Standard Siemens declarations of conformity for IEC/EN 60947 are available on request."},{"question":"Where can I buy 3RT6018-1AD02?","answer":"This contactor is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT6018-1AD02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT6018-1AD02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}