{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT6018-1AF02","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT6018-1AF02","canonicalUrl":"https://aoctrl.com/siemens/3RT6018-1AF02","factsUrl":"https://aoctrl.com/api/mcp/products/3RT6018-1AF02","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, power contactor, size S00, 3RT6018-1AF02, AC-3 rated 690 V, 13 kW at 400 V 60 °C, screw terminals, 45 mm width, 73 mm depth, 57.5 mm height.","salesMarkdown":"The AC-3 rating goes up to 690 V maximum, and at 400 V 60 °C it handles a 13 kW motor load — that's the number that matters for sizing on a three-phase induction motor driving a pump, fan, or conveyor. At 230 V 60 °C it's rated for 7.5 kW, and at 690 V 60 °C it reaches 22 kW. Screw terminals on the main current circuit accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm² solid or stranded copper. The minimum permissible cross-section at 40 °C is 4 mm², at 60 °C it's 2.5 mm² — so if your panel runs hot, you can drop a wire gauge and still stay within rating. Dimensions are 45 mm wide, 73 mm deep, 57.5 mm high — the S00 footprint. That 73 mm depth includes the coil terminals; leave clearance for wiring and a screwdriver. The 45 mm width matches a standard 45 mm DIN-rail module pitch, so it fills one slot in a typical motor starter row. The contactor is rated for 10,000 switching cycles per hour at AC, with a maximum of 1,000/h in AC-1 duty, 750/h in AC-3, and 250/h in AC-4. For high-cycle applications like a rapid-indexing conveyor, stay within the AC-3 maximum of 750/h to keep the contacts happy.","metaTitle":"Siemens 3RT6018-1AF02 SIRIUS Power Contactor, S00, 690V AC-3","metaDescription":"Siemens SIRIUS 3RT6018-1AF02 power contactor, size S00, rated 690V AC-3, 13kW at 400V 60°C. Screw terminals, DIN rail mount. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"10 000 1/h","Height":"57.5 mm","at 50 Hz":"0.25","at 60 Hz":"0.25","During Storage":"-55 ... +80 °C","at AC-1 maximum":"1 000 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","at AC-3e maximum":"750 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Power contactor","at 24 V rated value":"6 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 60 Hz rated value":"110 V","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-3 rated value maximum":"690 V","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"4 mm²","at 60 °C minimum permissible":"2.5 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"7.5 kW","at 400 V at 60 °C rated value":"13 kW","at 690 V at 60 °C rated value":"22 kW","for AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 20 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A","operational current at AC-12 maximum":"10 A","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","at ambient temperature 40 °C rated value":"22 A","at ambient temperature 60 °C rated value":"20 A","Type Of Voltage Of The Control Supply Voltage":"AC","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b6cafee1138985e9824b7c374ad16eac.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=579935&mlfb=3RT6018-1AF02","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT6018-1AF02/alternatives.json"},"ai":{"faq":[{"question":"What is the width and depth of this contactor?","answer":"Width is 45 mm, depth is 73 mm, height is 57.5 mm — the standard S00 footprint. The 45 mm width matches one DIN-rail slot."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT6018-1AF02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT6018-1AF02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}