{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT6024-1AR60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT6024-1AR60","canonicalUrl":"https://aoctrl.com/siemens/3RT6024-1AR60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT6024-1AR60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S0 power contactor, 3RT6024-1AR60, screw-type terminals, 45 mm wide, 23 kW at 400 V 60 °C AC-3.","salesMarkdown":"The Siemens 3RT6024-1AR60 is a SIRIUS S0-size power contactor with screw-type main circuit terminals, rated for AC-3 and AC-3e duty up to 690 V. It delivers 23 kW at 400 V and 40 kW at 690 V, both at 60 °C ambient — the temperature you'll see inside a closed panel, not the idealised 40 °C. That's the number to use for your motor sizing, not the 40 °C line. Coil draw at 50 Hz is 0.25 A, at 60 Hz it's 0.28 A — expect the higher figure in North American plants. The contactor snaps onto a 35 mm DIN rail per EN 50022 and can be rotated ±180° on a vertical surface, or tilted forward/backward ±22.5°, which helps when the gland plate crowds the panel layout. The auxiliary contact block carries 6 A at 24 V, 10 A at 230 V, and 3 A at 400 V — enough for a PLC input or a pilot relay, but watch the 690 V limit (1 A). Mechanical life is 10 million operations typical; electrical life at AC-3 is 1,000 operations per hour max, dropping to 300 for AC-4 (plugging/inching). If your application cycles faster than that, step up to a larger frame or a dedicated reversing contactor pair. Width is 45 mm, depth 97 mm, height 85 mm — fits a standard S0 footprint. Side-by-side mounting is allowed (no derating gap), so you can pack several in a row on the same DIN rail. Wire the main circuit with 10 mm² minimum at 60 °C; the screw terminals accept 2x 0.5–1.5 mm² or 2x 0.75–2.5 mm² for the coil/auxiliary connections. Strip length is not given here, but the 2x range suggests ferruled stranded for reliability. No IP rating is listed, so it's not for washdown or outdoor use without an enclosure.","metaTitle":"Siemens 3RT6024-1AR60 SIRIUS Power Contactor, S0, 23 kW at 4","metaDescription":"Siemens 3RT6024-1AR60 SIRIUS S0 power contactor, 23 kW at 400 V 60 °C, AC-3. Screw terminals, 45 mm wide. Active production. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"97 mm","Width":"45 mm","at AC":"5 000 1/h","Height":"85 mm","at 50 Hz":"0.25","at 60 Hz":"0.28","During Storage":"-55 ... +80 °C","at AC-1 maximum":"1 000 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","at AC-3e maximum":"1 000 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Power contactor","at 24 V rated value":"6 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 50 Hz rated value":"400 V","at 60 Hz rated value":"440 V","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-3 rated value maximum":"690 V","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"10 mm²","at 60 °C minimum permissible":"10 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"13.3 kW","at 400 V at 60 °C rated value":"23 kW","at 690 V at 60 °C rated value":"40 kW","for AWG cables for main contacts":"2x (16 ... 12), 2x (14 ... 8)","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 25 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 63 A","operational current at AC-12 maximum":"10 A","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","at ambient temperature 40 °C rated value":"40 A","at ambient temperature 60 °C rated value":"35 A","Type Of Voltage Of The Control Supply Voltage":"AC","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a8256945bcb5739635d1e2f4f296dff4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=580163&mlfb=3RT6024-1AR60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT6024-1AR60/alternatives.json"},"ai":{"faq":[{"question":"Will 3RT6024-1AR60 drop into a panel specified around 3RT6024-1AP00 without rewiring?","answer":"Both are SIRIUS S0-size contactors with the same 45 mm width, 97 mm depth, and screw-type main terminals, so the mechanical footprint and wiring pattern are identical. The difference is in the coil: 3RT6024-1AP00 uses a different coil voltage/frequency variant. Verify the coil rating matches your control voltage before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT6024-1AR60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT6024-1AR60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}