{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT6025-1BW40","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT6025-1BW40","canonicalUrl":"https://aoctrl.com/siemens/3RT6025-1BW40","factsUrl":"https://aoctrl.com/api/mcp/products/3RT6025-1BW40","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT6025-1BW40, S0 size, 48 VDC coil, screw-type terminals, rated 23 kW at 400 V AC-3.","salesMarkdown":"## Siemens 3RT6025-1BW40 — 48 VDC Coil Power Contactor, S0 Frame Its 48 VDC coil pulls in reliably across the rated control voltage range, and the screw-type main and auxiliary terminals accept up to 10 mm² conductors (2x 0.75…2.5 mm² stranded). Rated for AC-3 duty up to 690 V, this contactor delivers 23 kW at 400 V and 40 kW at 690 V. Operating temperature range -25…+60 °C; storage range -55…+80 °C covers most industrial environments. ## Switching Performance and Contact Ratings Maximum switching frequency: 1 000 cycles/hour for AC-1, AC-3, and AC-3e duty; 300 cycles/hour for AC-4 (plugging/inching); 1 500 cycles/hour for DC operation. The 48 VDC coil draws 6 A at 24 V rated value, 1 A at 110 V, 0.3 A at 220 V, and 10 A at 230 V — these are the contact ratings for the main poles, not the coil draw. Insulation voltage rated 690 V, pollution degree 3 suitable for industrial atmospheres. The contactor accepts auxiliary switch extensions (product extension auxiliary switch: yes), allowing add-on blocks for status feedback or interlocking without replacing the base unit.","metaTitle":"Siemens 3RT6025-1BW40 SIRIUS Power Contactor, 48 VDC Coil","metaDescription":"Siemens 3RT6025-1BW40 SIRIUS power contactor, 48 VDC coil, S0 size, screw terminals, 23 kW at 400 V AC-3. Active lifecycle, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"107 mm","Width":"45 mm","at DC":"1 500 1/h","title":"3RT6025-1BW40","Height":"85 mm","Rated Value":"48 V","description":"Contactor DC 48 V AC3 7.5 kW 400 V AUX contacts 1 NO +1 NC 3-pole, size S0 screw terminal","During Storage":"-55 ... +80 °C","at AC-1 maximum":"1 000 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","at AC-3e maximum":"1 000 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Power contactor","at 24 V rated value":"6 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-3 rated value maximum":"690 V","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"10 mm²","at 60 °C minimum permissible":"10 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"13.3 kW","at 400 V at 60 °C rated value":"23 kW","at 690 V at 60 °C rated value":"40 kW","for AWG cables for main contacts":"2x (16 ... 12), 2x (14 ... 8)","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 25 A","closing power of magnet coil at DC":"5.9 W","holding power of magnet coil at DC":"5.9 W","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 63 A","operational current at AC-12 maximum":"10 A","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","at ambient temperature 40 °C rated value":"40 A","at ambient temperature 60 °C rated value":"35 A","Type Of Voltage Of The Control Supply Voltage":"DC","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9631f7224bbcbd465568c8f3dd03fa5d.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=580183&mlfb=3RT6025-1BW40"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT6025-1BW40","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT6025-1BW40 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}