{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT7014-1AQ01","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT7014-1AQ01","canonicalUrl":"https://aoctrl.com/siemens/3RT7014-1AQ01","factsUrl":"https://aoctrl.com/api/mcp/products/3RT7014-1AQ01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT7014-1AQ01, Size S00, 3-pole contactor, AC-3 rated 6 A at 230 V / 3 A at 400 V, 690 V max, AC coil, screw terminals, IP20, 45 mm wide.","salesMarkdown":"The 3RT7014-1AQ01 is a SIRIUS S00-frame contactor — the smallest in Siemens' modular contactor family, sized for motor loads up to about 3 kW at 400 V AC-3. The 3-pole main contacts are rated 6 A at 230 V and 3 A at 400 V, with a maximum operating voltage of 690 V AC-3. That means it handles fractional-horsepower pumps, small conveyors, or fan starters inside a control panel where space is tight. AC coil draws 0.8 W on pickup and 0.27 W holding. Verify control voltage type before wiring. At 45 mm wide and 72 mm deep, it leaves room for a three-phase motor starter combination — add a thermal overload relay on the same rail and you've got a compact motor starter group. Screw terminals on both main and control circuits accept 2x 0.5–2.5 mm² solid or stranded, or 2x 0.5–1.5 mm² with ferrules. That's standard panel wire — no special crimp tools needed. ## Switching duty and coordination Rated for 750 switching cycles per hour at AC-3 (motor starting) and 250 at AC-4 (plugging/inching). That's typical for a general-purpose contactor — fine for normal start/stop duty, but if your application requires frequent jogging or reversing, check the AC-4 limit against your cycle rate. For short-circuit coordination: Type 1 requires a 35 A gG fuse (3NA), Type 2 requires 20 A. Auxiliary contacts are rated for PLC-level signals (17 V, 5 mA), so they can switch directly into a digital input without a separate interface relay — saves a component and a wiring step.","metaTitle":"Siemens 3RT7014-1AQ01 Contactor, S00, 3-Pole, 690V AC-3, 45m","metaDescription":"Siemens 3RT7014-1AQ01 S00 contactor, 3-pole, 690V AC-3 max, 6A at 230V. IP20, screw terminals, DIN rail mount. Active production, sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Width":"45 mm","Height":"57.5 mm","at 50 Hz":"0.27","at 60 Hz":"0.27","On The Front":"IP20","During Storage":"-25 ... +70 °C","Of The Terminal":"IP20","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-10 ... +55 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Degree Of Pollution":"3","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"380 V","at 60 Hz rated value":"380 V","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","Insulation Voltage Rated Value":"690 V","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"gL/gG NH 3NA: 20 A","closing power of magnet coil at DC":"0.8 W","holding power of magnet coil at DC":"0.27 W","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gL/gG NH 3NA: 35 A","shock resistance with sine pulse at AC":"9.8g / 5 ms, 5.9g / 10 ms","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"acceptability for PLC control (17 V, 5 mA)","Type Of Voltage Of The Control Supply Voltage":"AC","operating voltage at AC-3 rated value maximum":"690 V","operational current at DC-13 at 220 V rated value":"0.3 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"1","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"2.5 mm²","Connectable Conductor Cross-Section For Auxiliary Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1533850&mlfb=3RT7014-1AQ01","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT7014-1AQ01/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions of this contactor?","answer":"Width 45 mm, height 57.5 mm, depth 72 mm. It mounts on 35 mm DIN rail or with screws."},{"question":"Can I add auxiliary contacts to the 3RT7014-1AQ01?","answer":"Yes, the product extension for auxiliary switches is supported. You can snap on standard SIRIUS auxiliary contact blocks to add N/O or N/C contacts."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT7014-1AQ01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT7014-1AQ01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}