{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT7016-1AG01","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT7016-1AG01","canonicalUrl":"https://aoctrl.com/siemens/3RT7016-1AG01","factsUrl":"https://aoctrl.com/api/mcp/products/3RT7016-1AG01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT7016-1AG01 contactor, Size S00, 3-pole, AC-3 rated 690 V, screw-type terminals, IP20 finger-safe front and terminals.","salesMarkdown":"The Siemens 3RT7016-1AG01 is a 3-pole contactor in the S00 frame size, rated for AC-3 duty up to 690 V maximum operating voltage. The S00 frame keeps the footprint compact at 45 mm wide, 57.5 mm tall, and 72 mm deep — sized for DIN-rail enclosures where panel space is tight. Side-by-side mounting is permitted, so multiple contactors can pack tightly on the rail without derating for proximity heat. The AC-3 rated operating current at 400 V is 3 A, and at 230 V it is 6 A — these are the currents it can make and break under motor starting conditions (inrush up to 6-8x FLA). The main contacts are 3 NO (normally open) with no NC main contacts — standard for a motor-starting contactor. The auxiliary switch is available as a product extension, and the contact reliability is rated for PLC-level control (17 V, 5 mA), so it can drive a logic input directly without a separate interface relay. ## Coil and control supply The control supply voltage is AC type. The closing power of the magnet coil at DC is 0.8 W, and the holding power drops to 0.27 W — the lower holding power means less heat dissipated in the panel during continuous operation, which matters when contactors are ganged side-by-side. The coil can handle 50/60 Hz at 36 V rated value. The shock resistance is rated at 9.8g for 5 ms and 5.9g for 10 ms sine pulse — sufficient for most industrial machinery but worth checking if the contactor is mounted on a vibrating conveyor or press. No last-time-buy or allocation risk is indicated.","metaTitle":"Siemens 3RT7016-1AG01 Contactor, Size S00, 3-Pole, 690 V AC-","metaDescription":"Siemens 3RT7016-1AG01 contactor, Size S00, 3-pole, 690 V AC-3 max. Screw terminals, IP20. Active production. RFQ for current lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Width":"45 mm","Height":"57.5 mm","at 50 Hz":"0.27","at 60 Hz":"0.27","On The Front":"IP20","During Storage":"-25 ... +70 °C","Of The Terminal":"IP20","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-10 ... +55 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Degree Of Pollution":"3","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"36 V","at 60 Hz rated value":"36 V","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","Insulation Voltage Rated Value":"690 V","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"gL/gG NH 3NA: 20 A","closing power of magnet coil at DC":"0.8 W","holding power of magnet coil at DC":"0.27 W","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gL/gG NH 3NA: 35 A","shock resistance with sine pulse at AC":"9.8g / 5 ms, 5.9g / 10 ms","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"acceptability for PLC control (17 V, 5 mA)","Type Of Voltage Of The Control Supply Voltage":"AC","operating voltage at AC-3 rated value maximum":"690 V","operational current at DC-13 at 220 V rated value":"0.3 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"1","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"2.5 mm²","Connectable Conductor Cross-Section For Auxiliary Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1533862&mlfb=3RT7016-1AG01","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT7016-1AG01/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions for panel layout?","answer":"Width is 45 mm, height is 57.5 mm, depth is 72 mm. It mounts on 35 mm DIN rail per EN 50022."},{"question":"What is the maximum motor voltage this contactor can switch?","answer":"The AC-3 rated operating voltage maximum is 690 V, suitable for three-phase induction motors up to that line voltage."},{"question":"Does this contactor have screw terminals or spring-cage terminals?","answer":"It has screw-type terminals for both the main current circuit and the auxiliary/control circuit. The terminals accept 2x (0.5 to 1.5 mm²) solid or stranded wire, or 2x (0.75 to 2.5 mm²) with ferruled ends."},{"question":"Can this contactor be mounted side-by-side with others without derating?","answer":"Yes, side-by-side mounting is permitted. The low holding power of 0.27 W helps keep heat buildup manageable in tight groupings."},{"question":"What fuse rating is required for type 2 coordination?","answer":"For type of coordination 2, the required fuse is gL/gG NH 3NA rated 20 A. For type of coordination 1, the rating is 35 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT7016-1AG01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT7016-1AG01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}