{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT7016-1AQ02","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT7016-1AQ02","canonicalUrl":"https://aoctrl.com/siemens/3RT7016-1AQ02","factsUrl":"https://aoctrl.com/api/mcp/products/3RT7016-1AQ02","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT7 Size S00 contactor, 3RT7016-1AQ02, 3-pole, screw terminals, AC-3 rated 6 A at 230 V / 3 A at 400 V, snap-on 35 mm DIN rail, IP20, current production.","salesMarkdown":"## Integrator note — 3RT7016-1AQ02 Three main NO poles handle AC-3 duty up to 6 A at 230 V, 3 A at 400 V, and 1 A at 690 V — so it covers small three-phase motors up to roughly 2.2 kW at 400 V. The coil draws 0.8 W on close, holding at 0.27 W DC, which keeps heat inside a crowded enclosure manageable. Mounting is screw-and-snap-on onto 35 mm DIN rail per EN 50022, with ±180° rotation on a vertical surface and ±22.5° tilt forward/backward — useful when the panel layout forces an odd orientation. Terminals are screw-type on both main and auxiliary circuits, accepting 2x (0.5…1.5 mm²) solid or 2x (0.75…2.5 mm²) stranded. ## Switching duty and coordination AC-3 maximum switching frequency is 750 operations per hour; AC-4 drops to 250 per hour. For standard motor starting (AC-3), the 750 ops/h ceiling is generous for most conveyor or pump cycles. With type of coordination 1, the required upstream fuse is gL/gG NH 3NA 35 A; with type 2 coordination it's 20 A. That distinction matters for selectivity design — type 2 limits downstream damage after a fault, so the 20 A fuse is the tighter choice when the panel must survive a short without replacing the contactor. ## Environmental and handling Operating temperature range is -10 to +55 °C; storage from -25 to +70 °C. Shock resistance is 9.8g / 5 ms sine pulse on AC, adequate for most industrial vibration profiles. Dimensions are 45 mm wide, 57.5 mm tall, 72 mm deep — the 72 mm depth is the key panel clearance figure; ensure the enclosure door or backplate has that much space behind the DIN rail. The S00 frame size is the smallest in the 3RT7 series, so it fits compact subpanels where every millimeter counts.","metaTitle":"Siemens 3RT7016-1AQ02 Contactor, Size S00, 3-Pole, 230V AC-3","metaDescription":"Siemens 3RT7016-1AQ02 Size S00 contactor, 3-pole, 6A at 230V AC-3, 3A at 400V AC-3. Screw terminals, IP20, snap-on 35mm DIN rail. Current production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Width":"45 mm","Height":"57.5 mm","at 50 Hz":"0.27","at 60 Hz":"0.27","On The Front":"IP20","During Storage":"-25 ... +70 °C","Of The Terminal":"IP20","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-10 ... +55 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","at AC-3e maximum":"750 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Degree Of Pollution":"3","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"380 V","at 60 Hz rated value":"380 V","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-3 rated value maximum":"690 V","at AC-3e rated value maximum":"690 V","Insulation Voltage Rated Value":"690 V","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"gL/gG NH 3NA: 20 A","closing power of magnet coil at DC":"0.8 W","holding power of magnet coil at DC":"0.27 W","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gL/gG NH 3NA: 35 A","shock resistance with sine pulse at AC":"9.8g / 5 ms, 5.9g / 10 ms","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"acceptability for PLC control (17 V, 5 mA)","Type Of Voltage Of The Control Supply Voltage":"AC","operational current at DC-13 at 220 V rated value":"0.3 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"0","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"2.5 mm²","Connectable Conductor Cross-Section For Auxiliary Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1533875&mlfb=3RT7016-1AQ02","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT7016-1AQ02/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the 3RT7016-1AQ02?","answer":"Sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an inquiry for the latest position."},{"question":"What are the AC-3 current ratings for 3RT7016-1AQ02?","answer":"Rated 6 A at 230 V, 3 A at 400 V, and 1 A at 690 V AC-3. The 400 V figure (3 A) is the typical selection point for a 2.2 kW three-phase motor in a 400 V system."},{"question":"What is the depth of the 3RT7016-1AQ02?","answer":"72 mm. That's the dimension from the DIN rail mounting surface to the furthest point of the contactor body — critical for enclosure depth clearance."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT7016-1AQ02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT7016-1AQ02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}