{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT7017-1AB02","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT7017-1AB02","canonicalUrl":"https://aoctrl.com/siemens/3RT7017-1AB02","factsUrl":"https://aoctrl.com/api/mcp/products/3RT7017-1AB02","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT7017-1AB02, size S00 contactor, 3-pole, 24 V AC 50/60 Hz coil, screw terminals, rated operational current 6 A at 400 V AC-3, IP20, DIN EN 50022 rail mount.","salesMarkdown":"## S00 contactor for motor switching up to 690 V AC-3 The Siemens 3RT7017-1AB02 is a SIRIUS size S00 contactor — the smallest frame in the SIRIUS family — with three main NO poles and a 24 V AC 50/60 Hz coil. Its AC-3 rated operational current of 6 A at 400 V covers fractional-horsepower motors up to roughly 2.2 kW at 400 V three-phase; the same contactor also carries 3 A at 400 V AC-4 for reversing or inching duty where the load is switched under full stall current. The 690 V AC-3 rating drops to 1 A, so it handles 690 V motor circuits only at light loads. The 24 V AC coil draws 0.27 A at both 50 Hz and 60 Hz, with a holding power of just 0.27 W DC — negligible thermal load inside a crowded panel. The coil closing power is 0.8 W DC. Its 45 mm width and 57.5 mm height leave a compact footprint; the 72 mm depth means it clears most 80 mm deep enclosures. Screw terminals on both main and auxiliary circuits accept 2 x (0.5 to 2.5 mm²) solid or stranded, or 2 x (0.5 to 1.5 mm²) finely stranded with ferrule. ## Protection coordination and auxiliary contacts For type of coordination 2 (no welding after short circuit), the required backup fuse is a gL/gG NH 3NA: 20 A. For type of coordination 1 (welding allowed), the same fuse type is 35 A. The contactor is rated for surge voltage withstand of 6 kV, which aligns with installation category III in a 400 V distribution panel. Auxiliary contact blocks can be added (product extension auxiliary switch is supported). The built-in auxiliary contacts are rated for PLC-level switching: acceptable for 17 V, 5 mA, so they can directly drive a 24 V DC PLC input without an interposing relay. The maximum switching frequency is 750 operations per hour at AC-3 and 250 at AC-4. ## Environmental and shock ratings Operating temperature range is -10 to +55 °C; storage from -25 to +70 °C. The contactor withstands 9.8 g for 5 ms and 5.9 g for 10 ms sine-pulse shock — sufficient for most industrial panel applications, including those mounted on machinery subject to vibration.","metaTitle":"Siemens 3RT7017-1AB02 Contactor S00, 24 V AC, 3-pole, 6 A AC","metaDescription":"Siemens 3RT7017-1AB02 SIRIUS contactor, size S00, 3-pole, 24 V AC coil, 6 A rated operational current at 400 V AC-3. IP20, screw terminals, DIN-rail mount. Active production, sourc","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Width":"45 mm","Height":"57.5 mm","at 50 Hz":"0.27","at 60 Hz":"0.27","On The Front":"IP20","During Storage":"-25 ... +70 °C","Of The Terminal":"IP20","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-10 ... +55 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Degree Of Pollution":"3","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","Insulation Voltage Rated Value":"690 V","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"gL/gG NH 3NA: 20 A","closing power of magnet coil at DC":"0.8 W","holding power of magnet coil at DC":"0.27 W","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gL/gG NH 3NA: 35 A","shock resistance with sine pulse at AC":"9.8g / 5 ms, 5.9g / 10 ms","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"acceptability for PLC control (17 V, 5 mA)","Type Of Voltage Of The Control Supply Voltage":"AC","operating voltage at AC-3 rated value maximum":"690 V","operational current at DC-13 at 220 V rated value":"0.3 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"0","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"2.5 mm²","Connectable Conductor Cross-Section For Auxiliary Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1533881&mlfb=3RT7017-1AB02","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT7017-1AB02/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RT7017-1AB02?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is 3RT7017-1AB02's listed depth (72 mm) on this component line?","answer":"The depth is 72 mm, which fits most 80 mm deep enclosures without clearance issues."},{"question":"What is 3RT7017-1AB02's listed width (45 mm) on this component line?","answer":"The width is 45 mm — a single module width on a 35 mm DIN rail, allowing side-by-side mounting without derating."},{"question":"What compliance documentation does this brand provide for 3RT7017-1AB02 (RoHS, REACH, UL, IEC)?","answer":"The product is designed to IEC/EN 60947-4-1 standards. The insulation voltage is rated 690 V, surge voltage withstand is 6 kV, and the degree of pollution is 3. For specific RoHS/REACH declarations and UL file numbers, request the manufacturer's compliance documentation with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT7017-1AB02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT7017-1AB02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}