{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT7017-1AN22","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT7017-1AN22","canonicalUrl":"https://aoctrl.com/siemens/3RT7017-1AN22","factsUrl":"https://aoctrl.com/api/mcp/products/3RT7017-1AN22","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT7017-1AN22, size S00 contactor, 3-pole, AC-3 rated 6 A at 230 V, screw terminals, IP20, 45 mm width.","salesMarkdown":"It carries three normally open main contacts rated for AC-3 duty up to 690 V, with a rated operational current of 6 A at 230 V and 3 A at 400 V. This puts it squarely in the small-motor and light-load range — think fractional-horsepower pumps, small fans, or conveyor drives where the full-load amps stay under 6 A. The AC-3 rating is the one that matters for motor starting: 6 A at 230 V and 3 A at 400 V. AC-3 covers starting and disconnecting squirrel-cage motors under load, so that 6 A figure is the maximum continuous motor current the contactor can handle through start and run. For resistive loads (AC-1), you get a higher current, but the AC-3 number is the binding one for induction motors. The contactor also carries a 1 A rating at 690 V, which covers applications on higher-voltage systems like 690 V three-phase grids common in heavy industrial or mining. Switching frequency is capped at 750 operations per hour under AC-3 duty and 250 per hour under AC-4 (plugging or inching). That 750 ops/h is fine for a pump cycling on a level switch or a conveyor start-stop, but if you're doing rapid reversing or jogging, the AC-4 limit of 250 ops/h governs — exceed it and the arc erosion accelerates. The coil draws 0.27 W holding power at DC and a brief 0.8 W closing pulse, which is low enough to drive directly from a PLC output or a small control transformer without worrying about coil dropout. That 6 kV figure means it can handle the voltage spikes common in industrial panels with long motor cables or nearby VFDs — you don't need a separate surge suppressor for this contactor in most installations. ## Mounting and integration details Terminals are screw-type for both main and control circuits. Wire sizes accepted: 2x 0.5 to 1.5 mm² solid or stranded, or 2x 0.75 to 2.5 mm². That covers standard panel wiring up to about 14 AWG. For the main circuit, the recommended fuse is a gL/gG NH 3NA: 20 A for type 2 coordination (no damage to the contactor under short circuit) or 35 A for type 1 coordination (contactor may need replacement after a fault). The contactor accepts auxiliary switch blocks on the front, so you can add a feedback contact for the PLC or a status indicator.","metaTitle":"Siemens 3RT7017-1AN22 Contactor, Size S00, 3-Pole, 690 V, 6","metaDescription":"Siemens 3RT7017-1AN22 contactor, size S00, 3-pole main contacts, rated 6 A at 230 V AC-3. Screw terminals, IP20, DIN rail mount. Active lifecycle, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Width":"45 mm","title":"3RT7017-1AN22","Height":"57.5 mm","at 50 Hz":"0.27","at 60 Hz":"0.27","description":"Contactor AC-3 12A/5,5kW 400V 1NC AC 220V 50/60Hz size S00, screw terminal","On The Front":"IP20","During Storage":"-25 ... +70 °C","Of The Terminal":"IP20","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-10 ... +55 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","at AC-3e maximum":"750 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Degree Of Pollution":"3","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"220 V","at 60 Hz rated value":"220 V","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-3 rated value maximum":"690 V","at AC-3e rated value maximum":"690 V","Insulation Voltage Rated Value":"690 V","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"gL/gG NH 3NA: 20 A","closing power of magnet coil at DC":"0.8 W","holding power of magnet coil at DC":"0.27 W","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gL/gG NH 3NA: 35 A","shock resistance with sine pulse at AC":"9.8g / 5 ms, 5.9g / 10 ms","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"acceptability for PLC control (17 V, 5 mA)","Type Of Voltage Of The Control Supply Voltage":"AC","operational current at DC-13 at 220 V rated value":"0.3 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"0","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"2.5 mm²","Connectable Conductor Cross-Section For Auxiliary Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7c5b6133bc865c9f88c8f1c9360f9803.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1533893&mlfb=3RT7017-1AN22"},"ai":{"faq":[{"question":"What are the key ratings for 3RT7017-1AN22?","answer":"AC-3 rated operational current is 6 A at 230 V and 3 A at 400 V, with a maximum rated voltage of 690 V. The contactor has 3 normally open main poles, insulation voltage of 690 V, and surge voltage resistance of 6 kV."},{"question":"What is the physical size of 3RT7017-1AN22?","answer":"Width is 45 mm, height 57.5 mm, depth 72 mm. It is a size S00 contactor designed for snap-on mounting onto 35 mm DIN rail."},{"question":"Where can I buy 3RT7017-1AN22?","answer":"The contactor is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quote."},{"question":"What compliance documentation is available for 3RT7017-1AN22?","answer":"The contactor carries IP20 protection rating on front and terminals, pollution degree 3, and surge voltage resistance of 6 kV. Standard Siemens documentation including CE declaration and RoHS compliance is available upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT7017-1AN22","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT7017-1AN22 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}