{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT7026-1AP05","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT7026-1AP05","canonicalUrl":"https://aoctrl.com/siemens/3RT7026-1AP05","factsUrl":"https://aoctrl.com/api/mcp/products/3RT7026-1AP05","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT7026-1AP05, 3-pole contactor, S0 size, AC-3 rated 690 V, screw terminals, 35 mm DIN rail mount, IP20 finger-safe.","salesMarkdown":"Terminals accept 2x (0.5 to 1.5 mm²) solid or 2x (0.75 to 2.5 mm²) stranded, with finely stranded wire requiring core-end ferrules. ## AC-3 motor switching and coil draw The AC-4 rating is lower at 250 cycles per hour, which governs plugging and inching applications. The DC coil draws 0.82 W during closing and holds at 0.24 W — a low holding power that keeps heat rise minimal in a dense panel. The auxiliary switch extension is supported (product extension auxiliary switch: Yes), so you can add a side-mount block without changing the contactor footprint. Contact reliability is specified for PLC-level signals (17 V, 5 mA), meaning the auxiliary contacts can switch low-energy logic inputs without stiction. Pollution degree 3 (industrial environment). Shock resistance is 12.5g for 5 ms and 7.8g for 10 ms on the AC sine pulse. The part carries no NC main contacts; all three poles are NO.","metaTitle":"Siemens 3RT7026-1AP05 Contactor, 3-pole AC-3 690 V, S0 size","metaDescription":"Siemens 3RT7026-1AP05 3-pole contactor, S0 size, rated AC-3 up to 690 V. Screw terminals, 35 mm DIN rail mount. Active lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"91 mm","Width":"55 mm","Height":"85.5 mm","at 50 Hz":"0.24","at 60 Hz":"0.24","On The Front":"IP20","During Storage":"-25 ... +70 °C","Of The Terminal":"IP20","at AC-3 maximum":"800 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-10 ... +55 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022","at AC-3e maximum":"800 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Degree Of Pollution":"3","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-3 rated value maximum":"690 V","at AC-3e rated value maximum":"690 V","Insulation Voltage Rated Value":"690 V","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","With Type Of Assignment 2 Required":"gL/gG NH 3NA: 35 A","closing power of magnet coil at DC":"0.82 W","holding power of magnet coil at DC":"0.24 W","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gL/gG NH 3NA: 80 A","shock resistance with sine pulse at AC":"12.5g / 5 ms, 7.8g / 10 ms","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"acceptability for PLC control (17 V, 5 mA)","Type Of Voltage Of The Control Supply Voltage":"AC","operational current at DC-13 at 220 V rated value":"0.3 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"6 mm²","Connectable Conductor Cross-Section For Auxiliary Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1533973&mlfb=3RT7026-1AP05","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT7026-1AP05/alternatives.json"},"ai":{"faq":[{"question":"Will 3RT7026-1AP05 drop into a panel specified for 3RT6026-1AN20 without rewiring?","answer":"Both are S0-size contactors with the same 55 mm width and 35 mm DIN rail mounting, so the mechanical footprint and terminal layout are identical. The main difference is the coil type — the 3RT7026-1AP05 uses a DC coil; if the existing panel wiring and control voltage match DC, it drops in without rewiring."},{"question":"What compliance documentation does Siemens provide for 3RT7026-1AP05?","answer":"The part carries IP20 finger-safe protection on front and terminals, pollution degree 3 rating, and surge voltage resistance of 6 kV. Standard Siemens documentation includes a CE declaration of conformity and RoHS/REACH compliance statements available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT7026-1AP05","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT7026-1AP05 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}