{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RU1116-0HC1","brand":"Siemens","brandSlug":"siemens","productSlug":"3RU1116-0HC1","canonicalUrl":"https://aoctrl.com/siemens/3RU1116-0HC1","factsUrl":"https://aoctrl.com/api/mcp/products/3RU1116-0HC1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RU1116-0HC1 thermal overload relay, Class 10, size S00, 690 V AC-3, cage clamp terminals, IP20 front, stand-alone mount.","salesMarkdown":"## SIRIUS 3RU1116-0HC1 — thermal overload relay for motor protection ## Mounting and integration — S00 frame, stand-alone or direct to contactor The mounting position allows ±135° rotation and ±45° tilt on a vertical surface, giving panel builders flexibility in tight cabinets. Cage clamp terminals on the main circuit accept 2x (0.5... 2.5 mm²) solid or 2x (0.5... 1.5 mm²) finely stranded with ferrules — no screwdriver needed for the power connections, which speeds up wiring in high-density panels. Shock rated at 8g for 10 ms, and surge voltage resistance at 6 kV. The relay carries ATEX protection type DMT 98 ATEX G 001 for use in potentially explosive atmospheres, and is reference-coded per DIN EN 81346-2 as function F. Rated for installation altitudes up to 2 000 m without derating, and operates in up to 100 % relative humidity.","metaTitle":"Siemens 3RU1116-0HC1 SIRIUS Thermal Overload Relay, Class 10","metaDescription":"Siemens 3RU1116-0HC1 SIRIUS thermal overload relay, Class 10 trip, S00 frame, 690V AC-3, IP20 front, cage clamp terminals. Sourced to order — request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Overload Relays"],"specifications":{"Depth":"78 mm","Solid":"2x (0.5 ... 2.5 mm²)","Width":"45 mm","Height":"92 mm","Maximum":"2 000 m","Upwards":"0 mm","at 24 V":"1 A","Forwards":"0 mm","at 110 V":"0.22 A","at 120 V":"3 A","at 125 V":"0.22 A","at 220 V":"0.11 A","at 230 V":"2 A","at 400 V":"1 A","Backwards":"0 mm","Downwards":"0 mm","Trip class":"CLASS 10","At The Side":"6 mm","On The Front":"IP20","Mounting type":"stand-alone installation","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +70 °C","During Transport":"-55 ... +80 °C","Shock resistance":"8g / 10 ms","Mounting position":"with vertical mounting surface +/-135° rotatable, with vertical mounting surface +/- 45° tiltable to the front and back","Product brand name":"SIRIUS","Type of protection":"DMT 98 ATEX G 001","Product designation":"thermal overload relay","For Auxiliary Contacts":"0","Size of overload relay":"S00","For Main Current Circuit":"Cage Clamp terminals","at AC-3 rated value maximum":"690 V","at AC in hot operating state":"4.8 W","Relative humidity during operation":"100 %","at AWG conductors for main contacts":"2x (24 ... 14)","Surge voltage resistance rated value":"6 kV","Reference code acc. to DIN EN 81346-2":"F","at AC in hot operating state per pole":"1.6 W","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 14)","For Auxiliary And Control Current Circuit":"Cage Clamp terminals","Finely Stranded Without Core End Processing":"2x (0.5 ... 1.5 mm²)","Number of NC contacts for auxiliary contacts":"1","Number of NO contacts for auxiliary contacts":"1","Size of contactor can be combined company-specific":"S00","Removable Terminal For Auxiliary And Control Circuit":"No","Insulation voltage with degree of pollution 3 rated value":"690 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 6 A, quick: 10 A","Adjustable pick-up value current of the current-dependent overload release":"0.55 ... 0.8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=137448&mlfb=3RU1116-0HC1","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RU1116-0HC1/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the 3RU1116-0HC1 and get a price?","answer":"The 3RU1116-0HC1 is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time."},{"question":"What are the key ratings of the 3RU1116-0HC1?","answer":"It is a Class 10 thermal overload relay, size S00, rated for AC-3 duty up to 690 V. The front face is IP20, and main circuit connections use cage clamp terminals accepting 2x (0.5... 2.5 mm²) solid wire."},{"question":"What compliance documentation is available for the 3RU1116-0HC1?","answer":"The relay carries ATEX protection type DMT 98 ATEX G 001 for explosive atmospheres, and is reference-coded per DIN EN 81346-2. Standard Siemens declarations (RoHS, REACH, UL, IEC) are available on request."},{"question":"Will the 3RU1116-0HC1 drop into a panel specified around 3RH6131-1BF40?","answer":"No — the 3RH6131-1BF40 is a contactor, not an overload relay. The 3RU1116-0HC1 is the matching overload for S00 contactors and mounts directly onto them, but it is a different component class and cannot substitute a contactor."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RU1116-0HC1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RU1116-0HC1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}