{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RU1136-1JB0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RU1136-1JB0","canonicalUrl":"https://aoctrl.com/siemens/3RU1136-1JB0","factsUrl":"https://aoctrl.com/api/mcp/products/3RU1136-1JB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS thermal overload relay, 3RU1136-1JB0, CLASS 10, S2 size, screw terminals, IP20 front, ATEX certified.","salesMarkdown":"It mounts directly onto a contactor via the fastening method — no separate base needed — saving rail space and wiring. Rated surge voltage 6 kV gives the relay enough insulation coordination for 400 V line-to-line systems with upstream surge protection. Shock resistance of 8g / 10 ms means it holds calibration under moderate vibration — fine for floor-mounted MCCs, less so for direct engine mounting. The IP20 front protection keeps fingers and tools out but does not seal against dust or moisture; panel builders should place it inside an IP54 or higher enclosure. That covers most DIN-rail cabinet layouts without derating. Ambient operating range –20 to +70 °C with 100 % relative humidity (non-condensing) suits both heated indoor panels and unheated sheds. Screw terminals on both main and auxiliary circuits accept solid or stranded copper: main contacts up to 35 mm² (1x) or 25 mm² (2x), auxiliary contacts 0.5–2.5 mm². The AWG equivalents run 18–3 for mains and 20–14 for aux — covers typical motor leads and control wiring without adapters.","metaTitle":"Siemens 3RU1136-1JB0 SIRIUS Thermal Overload Relay, CLASS 10","metaDescription":"Siemens 3RU1136-1JB0 SIRIUS thermal overload relay, CLASS 10 trip, S2 size, IP20 front, ATEX approved. Active production. Quoted to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Overload Relays"],"specifications":{"Depth":"118 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Width":"55 mm","Height":"105 mm","Upwards":"0 mm","at 24 V":"1 A","Forwards":"0 mm","Per Pole":"2.5 W","Stranded":"2x (0.75 ... 25 mm²), 0.75 ... 35 mm²","at 110 V":"0.22 A","at 120 V":"3 A","at 125 V":"0.22 A","at 220 V":"0.11 A","at 230 V":"2 A","at 400 V":"1 A","Backwards":"0 mm","Downwards":"0 mm","Trip Class":"CLASS 10","At The Side":"6 mm","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +70 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Contactor mounting","Shock Resistance":"8g / 10 ms","Mounting Position":"with vertical mounting surface +/-135° rotatable, with vertical mounting surface +/- 45° tiltable to the front and back","Product Brand Name":"SIRIUS","Type Of Protection":"DMT 98 ATEX G 001","Product Designation":"thermal overload relay","Size Of Overload Relay":"S2","For Main Current Circuit":"screw-type terminals","Substance Prohibitance (Date)":"07/01/2006","at AWG cables for main contacts":"2x (18 ... 3), 1x (18 ... 1)","protection class IP on the front":"IP20","For Auxiliary And Control Circuit":"screw-type terminals","Relative Humidity During Operation":"100 %","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Touch Protection Against Electrical Shock":"finger-safe","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","Size Of Contactor Can Be Combined Company-Specific":"S2","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 6 A, quick: 10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","power loss [W] for rated value of the current at AC in hot operating state":"7.5 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"7 ... 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1eaab8c2078ebde54846cf18a442e13b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=424796&mlfb=3RU1136-1JB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RU1136-1JB0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RU1136-1JB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RU1136-1JB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}