{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RU2116-0JB0-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RU2116-0JB0-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RU2116-0JB0-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RU2116-0JB0-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RU2116-0JB0-ZW97 thermal overload relay, CLASS 10, size S00, 690 V rated, for contactor mounting, with integrated auxiliary switch.","salesMarkdown":"It mounts directly onto a contactor, forming a compact motor starter assembly. The integrated auxiliary switch provides a remote trip signal, and the unit includes a mechanical trip indicator that shows a \"Tripped\" message when the overload has operated. This overload relay is designed for direct contactor mounting — it snaps onto the bottom of a SIRIUS S00 contactor (e.g., 3RT6015 or 3RT6017 series) without additional wiring between the contactor and relay. The power terminals are screw-type, accepting 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²) solid or stranded conductors. The screwdriver tip required is Pozidriv PZ2, shaft diameter 5 to 6 mm. The relay includes temperature compensation over -40 to +60 °C, so the trip characteristic stays accurate across the operating range of the enclosure. The integrated auxiliary switch is rated for the following voltages and currents: 24 V at 2 A, 60 V at 0.3 A, 110 V at 0.22 A, 120 V at 3 A, 125 V at 0.22 A, 220 V at 0.11 A, 230 V at 2 A, and 400 V at 1 A. These ratings cover both AC and DC control circuits typically found in motor control centers.","metaTitle":"Siemens 3RU2116-0JB0-ZW97 SIRIUS Thermal Overload Relay, CLA","metaDescription":"Siemens SIRIUS 3RU2116-0JB0-ZW97 thermal overload relay, CLASS 10, size S00, for contactor mounting. Rated 690 V, with integrated auxiliary switch. Current production status. Avail","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"Tripped\"","Depth":"70 mm","Width":"45 mm","title":"3RU2116-0JB0-ZW97","Height":"76 mm","at 24 V":"2 A","at 60 V":"0.3 A","Per Pole":"1.6 W","at 110 V":"0.22 A","at 120 V":"3 A","at 125 V":"0.22 A","at 220 V":"0.11 A","at 230 V":"2 A","at 400 V":"1 A","Trip Class":"CLASS 10","Rated Value":"690 V","description":"Overload relay 0.70...1.0 A Thermal For motor protection Size S00, Class 10 Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset Multi-unit packaging Pack = 16 units","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-40 ... +70 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Contactor mounting","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"thermal overload relay","at 400 V rated value":"0.25 kW","at 480 V rated value":"1 A","at 500 V rated value":"0.37 kW","at 600 V rated value":"1 A","at 690 V rated value":"0.55 kW","Size Of Overload Relay":"S00","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-40 ... +60 °C","MTTF with high demand rate":"2 280 y","Design Of Screwdriver Shaft":"Diameter 5 ... 6 mm","Size Of The Screwdriver Tip":"Pozidriv PZ 2","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"1 A","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","For Auxiliary And Control Circuit":"screw-type terminals","Between Main And Auxiliary Circuit":"440 V","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Of The Auxiliary And Control Contacts":"M3","Between Auxiliary And Auxiliary Circuit":"440 V","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"8g / 11 ms","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3e at 400 V rated value":"1 A","Size Of Contactor Can Be Combined Company-Specific":"S00","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A, quick: 10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","power loss [W] for rated value of the current at AC in hot operating state":"4.8 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.7 ... 1 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/262bc7911089cb9e9fcec041be581551.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=884090&mlfb=3RU2116-0JB0-ZW97"},"ai":{"faq":[{"question":"What is the trip class of 3RU2116-0JB0-ZW97?","answer":"It is CLASS 10, meaning it will trip within 10 seconds at 7.2× the set current — suitable for standard induction motors driving pumps, fans, and compressors."},{"question":"What does the 'Tripped' message on 3RU2116-0JB0-ZW97 mean?","answer":"The relay has a mechanical trip indicator that displays a 'Tripped' message when the overload has operated, providing a clear visual confirmation at the device."},{"question":"What is the mounting method for 3RU2116-0JB0-ZW97?","answer":"It mounts directly onto a SIRIUS S00 contactor (contactor mounting), with no additional wiring needed between the contactor and relay. Mounting position is any orientation."},{"question":"Where can I buy 3RU2116-0JB0-ZW97 and get current pricing?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RU2116-0JB0-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RU2116-0JB0-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}