{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RU2116-0JB0-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RU2116-0JB0-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RU2116-0JB0-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RU2116-0JB0-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS thermal overload relay, Size S00, Trip Class 10, 3RU2116-0JB0-ZX95, 690 V rated, 2 A at 24 V, contactor mounting, screw-type terminals.","salesMarkdown":"The Siemens 3RU2116-0JB0-ZX95 is a SIRIUS thermal overload relay in Size S00, Trip Class 10, designed to protect motors against overload and phase failure by monitoring current and tripping the associated contactor when the thermal model reaches the trip threshold — the note on this variant reads \"for message 'Tripped'\", meaning it provides a dedicated signal output when the relay has operated. Rated for a main circuit voltage of 690 V, it carries switching capacities that vary with the control voltage: 2 A at 24 V, 3 A at 120 V, 2 A at 230 V, 1 A at 400 V, and 0.75 A at 690 V, among other points — these are the currents the integrated auxiliary switch can break, not the motor full-load current the overload relay is set to protect. Motor power ratings are given for several line voltages: 0.25 kW at 400 V, 0.37 kW at 500 V, and 0.55 kW at 690 V, all under AC-3e duty at the maximum rated voltage of 690 V. Mounts directly onto a contactor via the contactor mounting fastening method — no DIN rail required, which saves panel width when paired with a matching SIRIUS contactor. Main circuit connections use screw-type terminals sized for M3 screws; the terminal accepts 2 x (0.5 to 1.5 mm²) or 2 x (0.75 to 2.5 mm²) solid or stranded wire. The screwdriver spec calls for a Pozidriv PZ2 tip with a shaft diameter of 5 to 6 mm. MTTF under high-demand rate is 2,280 years.","metaTitle":"Siemens 3RU2116-0JB0-ZX95 SIRIUS Thermal Overload Relay, Siz","metaDescription":"Siemens 3RU2116-0JB0-ZX95 SIRIUS thermal overload relay, Size S00, Trip Class 10. Rated 690 V, 2 A at 24 V. Contactor mounting, screw terminals. Current lifecycle; sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"Tripped\"","Depth":"70 mm","Width":"45 mm","title":"3RU2116-0JB0-ZX95","Height":"76 mm","at 24 V":"2 A","at 60 V":"0.3 A","Per Pole":"1.6 W","at 110 V":"0.22 A","at 120 V":"3 A","at 125 V":"0.22 A","at 220 V":"0.11 A","at 230 V":"2 A","at 400 V":"1 A","at 690 V":"0.75 A","Trip Class":"CLASS 10","Rated Value":"690 V","description":"Overload relay 0.70...1.0 A Thermal For motor protection Size S00, Class 10 Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset Reusable packaging Pack = 64 units","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-40 ... +70 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Contactor mounting","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"thermal overload relay","at 400 V rated value":"0.25 kW","at 480 V rated value":"1 A","at 500 V rated value":"0.37 kW","at 600 V rated value":"1 A","at 690 V rated value":"0.55 kW","Size Of Overload Relay":"S00","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-40 ... +60 °C","MTTF with high demand rate":"2 280 a","Design Of Screwdriver Shaft":"Diameter 5 ... 6 mm","Size Of The Screwdriver Tip":"Pozidriv PZ 2","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"1 A","for AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","For Auxiliary And Control Circuit":"screw-type terminals","Between Main And Auxiliary Circuit":"440 V","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"6 kV","Of The Auxiliary And Control Contacts":"M3","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Between Auxiliary And Auxiliary Circuit":"440 V","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"8g / 11 ms","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3e at 400 V rated value":"1 A","Size Of Contactor Can Be Combined Company-Specific":"S00","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A, quick: 10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","power loss [W] for rated value of the current at AC in hot operating state":"4.8 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.7 ... 1 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f6d3dfd3025415b52ed17eb59ddc8102.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=40011&mlfb=3RU2116-0JB0-ZX95"},"ai":{"faq":[{"question":"What is the note \"for message 'Tripped'\" on the 3RU2116-0JB0-ZX95?","answer":"The note indicates this variant includes a dedicated signal output that activates when the overload relay has tripped, providing a clear status indication for the control system."},{"question":"What compliance documentation does Siemens provide for 3RU2116-0JB0-ZX95?","answer":"The part has a substance prohibitance date of 10/01/2009, confirming RoHS compliance from that date. Standard Siemens documentation includes the declaration of conformity and CE marking per the Low Voltage Directive."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RU2116-0JB0-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RU2116-0JB0-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}