{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RU2116-0JB1","brand":"Siemens","brandSlug":"siemens","productSlug":"3RU2116-0JB1","canonicalUrl":"https://aoctrl.com/siemens/3RU2116-0JB1","factsUrl":"https://aoctrl.com/api/mcp/products/3RU2116-0JB1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RU2116-0JB1 thermal overload relay, Size S00, Class 10, 690 V rated, 1.6 W per pole, screw terminals, auxiliary switch integrated.","salesMarkdown":"## Trip class and motor protection timing The 3RU2116-0JB1: The thermal overload release design (bimetal + heater) provides inverse-time protection that tracks the motor's actual heating profile, not a fixed threshold. ## Panel footprint and mounting Size S00 frame — 45 mm wide, 89 mm tall, 80 mm deep — fits the standard SIRIUS S00 mounting footprint used across contactors and relays in this series. ## Auxiliary contact ratings across control voltages The note \"for message 'Tripped'\" indicates this auxiliary contact is wired specifically to signal the tripped state back to the PLC or annunciator, not the reset or test position. ## Environmental range and temperature compensation Operating ambient -40…+70 °C with temperature compensation active over -40…+60 °C — the compensation circuit corrects the trip point for ambient changes so the motor protection stays accurate regardless of panel heat or outdoor installation. Storage and transport range -55…+80 °C — wide enough for unheated warehouses or container shipping across climate zones.","metaTitle":"Siemens 3RU2116-0JB1 SIRIUS Thermal Overload Relay, Class 10","metaDescription":"Siemens 3RU2116-0JB1 SIRIUS thermal overload relay, Class 10, Size S00, 690 V rated, 1.6 W per pole. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"Tripped\"","Depth":"80 mm","Width":"45 mm","title":"3RU2116-0JB1","Height":"89 mm","at 24 V":"2 A","at 60 V":"0.3 A","Per Pole":"1.6 W","at 110 V":"0.22 A","at 120 V":"3 A","at 125 V":"0.22 A","at 220 V":"0.11 A","at 230 V":"2 A","at 400 V":"1 A","Trip Class":"CLASS 10","Rated Value":"690 V","description":"Overload relay 0.70...1.0 A Thermal For motor protection Size S00, Class 10 Stand-alone installation Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-40 ... +70 °C","During Transport":"-55 ... +80 °C","Fastening Method":"stand-alone installation","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"thermal overload relay","at 400 V rated value":"0.25 kW","at 480 V rated value":"1 A","at 500 V rated value":"0.37 kW","at 600 V rated value":"1 A","at 690 V rated value":"0.55 kW","Size Of Overload Relay":"S00","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-40 ... +60 °C","MTTF with high demand rate":"2 280 y","Design Of Screwdriver Shaft":"Diameter 5 ... 6 mm","Size Of The Screwdriver Tip":"Pozidriv PZ 2","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"1 A","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","For Auxiliary And Control Circuit":"screw-type terminals","Between Main And Auxiliary Circuit":"440 V","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Of The Auxiliary And Control Contacts":"M3","Between Auxiliary And Auxiliary Circuit":"440 V","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"8g / 11 ms","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3e at 400 V rated value":"1 A","Size Of Contactor Can Be Combined Company-Specific":"S00","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A, quick: 10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","power loss [W] for rated value of the current at AC in hot operating state":"4.8 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.7 ... 1 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$36.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a0029444df5afc5c939b7564f54526e8.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=284512&mlfb=3RU2116-0JB1"},"ai":{"faq":[{"question":"Will 3RU2116-0JB1 drop into a panel specified around 6ED1052-1MD08-0BA1 without rewiring?","answer":"No — 6ED1052-1MD08-0BA1 is a LOGO! logic module, not an overload relay. The 3RU2116-0JB1 is a thermal overload relay with a completely different form factor, wiring scheme, and function. Panel rewiring and a different mounting footprint would be required."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RU2116-0JB1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RU2116-0JB1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}