{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RU2116-1DC0-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RU2116-1DC0-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RU2116-1DC0-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RU2116-1DC0-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RU2116-1DC0-ZW97 thermal overload relay, CLASS 10, Size S00, 690 V rated, spring-loaded terminals, for message \"Tripped\".","salesMarkdown":"## CLASS 10 trip and the \"Tripped\" message The 3RU2116-1DC0-ZW97: That's the standard speed for general-purpose motor starting where the start-up transient doesn't exceed a few seconds. The note \"for message 'Tripped'\" on this variant means the auxiliary contact configuration is wired to signal a trip condition back to the PLC or annunciator, rather than directly dropping out the contactor coil. ## S00 frame mounts direct to contactor Size S00 frame — 45 mm wide, 87 mm tall, 70 mm deep — mounts directly onto the matching SIRIUS contactor via the fastening method listed as \"contactor mounting.\" No DIN rail bracket needed; the relay clips onto the contactor's front face, saving one DIN rail position per motor branch. No screw torque to verify — push the stripped wire in and the cage clamps it. The screwdriver shaft diameter is 3 mm with a 3.0 x 0.5 mm tip for the release slot if you need to open the clamp. ## Thermal design and ambient compensation The overload release is thermal — a bimetallic strip bends with heat from the motor current. Temperature compensation from -40 to +60 °C keeps the trip curve accurate across the panel's ambient range, so a hot panel doesn't cause nuisance tripping. Power dissipation per pole is 1.9 W at rated current. For a three-pole relay that's 5.7 W total — negligible for panel thermal budgeting, but worth noting if the enclosure is sealed and densely packed. Mounting position is any orientation. ## Active production — sourced per RFQ Sourced through authorized distribution channels against your BOM quantity. MTTF with high demand rate is 2,280 years — essentially a fit-and-forget component in the motor branch circuit. The relay is designed for the full service life of the panel.","metaTitle":"Siemens 3RU2116-1DC0-ZW97 SIRIUS Overload Relay, CLASS 10","metaDescription":"Siemens 3RU2116-1DC0-ZW97 SIRIUS thermal overload relay, CLASS 10 trip, S00 frame, spring terminals. Active production — sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"Tripped\"","Depth":"70 mm","Width":"45 mm","title":"3RU2116-1DC0-ZW97","Height":"87 mm","at 24 V":"2 A","at 60 V":"0.3 A","Per Pole":"1.9 W","at 110 V":"0.22 A","at 120 V":"3 A","at 125 V":"0.22 A","at 220 V":"0.11 A","at 230 V":"2 A","at 400 V":"1 A","Trip Class":"CLASS 10","Rated Value":"690 V","description":"Overload relay 2.2...3.2 A Thermal For motor protection Size S00, Class 10, Contactor mounting Auxiliary circuit: spring-type terminal Auxiliary circuit: spring-type terminal Manual-Automatic-Reset Multi-unit packaging Pack = 12 units","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-40 ... +70 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Contactor mounting","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"thermal overload relay","at 400 V rated value":"1.1 kW","at 480 V rated value":"3.2 A","at 500 V rated value":"1.5 kW","at 600 V rated value":"3.2 A","at 690 V rated value":"2.2 kW","Size Of Overload Relay":"S00","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-40 ... +60 °C","MTTF with high demand rate":"2 280 y","Design Of Screwdriver Shaft":"Diameter 3 mm","Size Of The Screwdriver Tip":"3,0 x 0,5 mm","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"3.2 A","at AWG cables for main contacts":"1x (20 ... 12)","For Auxiliary And Control Circuit":"spring-loaded terminals","Between Main And Auxiliary Circuit":"440 V","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 14)","Between Auxiliary And Auxiliary Circuit":"440 V","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Finely Stranded Without Core End Processing":"2x (0.5 ... 1.5 mm²)","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"8g / 11 ms","operational current at AC-3e at 400 V rated value":"3.2 A","Size Of Contactor Can Be Combined Company-Specific":"S00","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A, quick: 10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","power loss [W] for rated value of the current at AC in hot operating state":"5.7 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.2 ... 3.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8f1f7c9a4aeae0c3263eaf05453bd931.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=689156&mlfb=3RU2116-1DC0-ZW97"},"ai":{"faq":[{"question":"What does the 'Tripped' message mean on this overload relay?","answer":"The 'Tripped' note indicates the auxiliary contact configuration is wired to signal a trip condition — the relay has operated due to an overload."},{"question":"What is the physical size of 3RU2116-1DC0-ZW97?","answer":"Size S00 frame: 45 mm wide, 87 mm tall, 70 mm deep. Mounts directly onto the matching SIRIUS contactor — no DIN rail required."},{"question":"What compliance documentation does Siemens provide for this relay?","answer":"The evidence lists a substance prohibitance date of 10/01/2009, indicating RoHS compliance. Standard Siemens SIRIUS documentation includes CE, UL, CSA, and IEC certifications — request the specific declaration at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RU2116-1DC0-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RU2116-1DC0-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}