{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RU2116-1DC0-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RU2116-1DC0-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RU2116-1DC0-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RU2116-1DC0-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RU2116-1DC0-ZX95 thermal overload relay, CLASS 10, size S00, 690 V rated, spring-loaded terminals, integrated auxiliary switch with trip indication.","salesMarkdown":"## Trip indication and motor protection logic The 3RU2116-1DC0-ZX95 carries a note for message \"Tripped\" — the integrated auxiliary switch signals the PLC or HMI directly when the relay operates, so the control system knows the motor dropped off without polling the overload via the power circuit. ## Auxiliary contact ratings for signal compatibility At 60 V the contact is rated 0.3 A, and at 110 V or 125 V it carries 0.22 A — useful for legacy 110 VDC control circuits or specialised 60 V signalling. ## S00 footprint and wiring Size S00 with 70 mm depth, 45 mm width, and 87 mm height — this mounts directly onto the matching S00 contactor (e.g. 3RT201) without extra brackets, saving DIN-rail space. The relay carries a substance prohibitance date of 10/01/2009, indicating RoHS compliance from that date onward.","metaTitle":"Siemens 3RU2116-1DC0-ZX95 SIRIUS Overload Relay, CLASS 10","metaDescription":"Siemens 3RU2116-1DC0-ZX95 SIRIUS thermal overload relay, CLASS 10 trip, 690 V rated, spring terminals. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"Tripped\"","Depth":"70 mm","Width":"45 mm","title":"3RU2116-1DC0-ZX95","Height":"87 mm","at 24 V":"2 A","at 60 V":"0.3 A","Per Pole":"1.9 W","at 110 V":"0.22 A","at 120 V":"3 A","at 125 V":"0.22 A","at 220 V":"0.11 A","at 230 V":"2 A","at 400 V":"1 A","Trip Class":"CLASS 10","Rated Value":"690 V","description":"Overload relay 2.2...3.2 A Thermal For motor protection Size S00, Class 10, Contactor mounting Auxiliary circuit: spring-type terminal Auxiliary circuit: spring-type terminal Manual-Automatic-Reset Reusable packaging Pack = 56 units","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-40 ... +70 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Contactor mounting","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"thermal overload relay","at 400 V rated value":"1.1 kW","at 480 V rated value":"3.2 A","at 500 V rated value":"1.5 kW","at 600 V rated value":"3.2 A","at 690 V rated value":"2.2 kW","Size Of Overload Relay":"S00","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-40 ... +60 °C","MTTF with high demand rate":"2 280 y","Design Of Screwdriver Shaft":"Diameter 3 mm","Size Of The Screwdriver Tip":"3,0 x 0,5 mm","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"3.2 A","at AWG cables for main contacts":"1x (20 ... 12)","For Auxiliary And Control Circuit":"spring-loaded terminals","Between Main And Auxiliary Circuit":"440 V","Relative Humidity During Operation":"10 ... 95 %","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 14)","Between Auxiliary And Auxiliary Circuit":"440 V","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Finely Stranded Without Core End Processing":"2x (0.5 ... 1.5 mm²)","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"8g / 11 ms","operational current at AC-3e at 400 V rated value":"3.2 A","Size Of Contactor Can Be Combined Company-Specific":"S00","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A, quick: 10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"No","power loss [W] for rated value of the current at AC in hot operating state":"5.7 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.2 ... 3.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/55ba846213868ba3ffcbf81462a4bb1f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=683174&mlfb=3RU2116-1DC0-ZX95"},"ai":{"faq":[{"question":"What does the note 'for message Tripped' mean on the 3RU2116-1DC0-ZX95?","answer":"It means the integrated auxiliary switch provides a dedicated signal output that changes state when the overload relay trips, so the control system receives a direct 'tripped' indication without needing to sense motor current separately."},{"question":"What is the closest alternative to the 3RU2116-1DC0-ZX95 in the SIRIUS family?","answer":"The standard 3RU2116-1DC0 (without the -ZX95 suffix) is the base variant. The -ZX95 suffix typically indicates a special version or custom configuration — confirm the specific BOM requirement before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RU2116-1DC0-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RU2116-1DC0-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}